background image

2

APPLICATION

The  Night  vision  Monocular  is  a  complex  opticoelectronic  system  for  individual  use.  The 

device consists of the objective lens assembly, eyepiece and the body. The body contains 

a 1st (MO-41) or 2nd Gen. + (MO-42) image intensifier tube assembly with an integrated 

high voltage power source and the three volt battery housing. When installing the battery one 

should keep in mind that the polarity of the battery should coincide with the diagram on the 

body next to the battery housing cap.
Objective  lens  protective  cover  is  intended  to  protect  the  objective  lens  from  dust  and 

scratches. It will also act as a daylight filter, allowing you to test the scope in daylight or other 

bright light situations. The pin-hole in the center of the protective cover allows the user to 

check the operation ability of the device in daylight conditions.

NOTE: Do not test the scope in daylight conditions even with the daylight filter/lens cap 

on for more than ten (10) minutes.

SMART DIGITAL TECHNOLOGY

Smart Total Darkness Technology finally provides the user total control in the hi-tech industry 

of Night Vision. The Smart Series Night Vision scopes have been designed according to the 

latest computer technology.
Onboard computer systems identify the users intention of looking through the scope. When 

the scope is brought to the user’s eye, the scope automatically turn on. When removed from 

the eye the scope turns off (you must engage the proximity sensor for this feature to work). 

The user will never have to worry about turning his or her scope on or off. Smart series scopes 

automatically sense when they are no longer used and will shut off and enter their sleep mode. 

All the controls and buttons are digital. Even if your batteries are low, don’t worry the smart 

series will let you know. Our MO-4 scope has a 3-button digital control panel that allows the 

user to easily engage the main power, Infra-red illuminator and the proximity sensor. Color 

coded LEDs let you know the mode of operation you are using.
1. ON/OFF indicator light – when power is ON the LED is green.
2. When the proximity sensor is activated the LED will change to red.
3. When IR is ON the IR LED is orange.

NOTE, FOR MO-41:

 You may notice a persistent green glow for up to five (5) minutes after you 

have turned the MO-41 off. This is normal for the 1st Gen. light intensifier tube.

FOCUSING

To focus the MO-4 first you will need to adjust the diopter. Simply turn the diopter clockwise 

until it stops. Then, while looking through the diopter at a subject, slowly turn the diopter back 

counter clockwise until the grain in the image is sharp.

NOTE: 

We suggest that you focus the diopter during daylight with the filter on.

Next. When you are in low-light conditions and the daylight filter is off, you may focus the front 

lens to receive a sharp image, the diopter should not be adjusted.

NOTE: 

The front lens should be readjusted as you view objects at different distances.

INFRA-RED (IR) ILLUMINATION

Infra-red  illuminators,  or  IR  illuminators,  are  common  in  night  vision.  The  IR  light  greatly 

enhances the performance of the MO-4 while remaining almost totally invisible to the naked eye. 

The IR illuminator on the MO-4 is located to the side of the battery compartment.
To turn the IR on push the IR button and you will see an orange indicator light come on. It is 

important to remember that the IR illuminator is simply an infra red light source, and like any 

light source it may loose its effectiveness over a great distance.

Содержание Night vision Monocular MO-4

Страница 1: ...AMERICAN TECHNOLOGIES NETWORK CORP u s e r s g u i d e MO 4...

Страница 2: ...lity for any errors or inaccuracies that may appear in this book 2001 ATN Corp All right reserved Power button Digital control for IR Digital control for Proximity Sensor Objective lens protective cov...

Страница 3: ...and enter their sleep mode All the controls and buttons are digital Even if your batteries are low don t worry the smart series will let you know Our MO 4 scope has a 3 button digital control panel t...

Страница 4: ...he rubber eye cup from the MO 4 Screw the camera adapter onto the front of the lens on your Video camera s lens or your 35 mm camera s lens Loosen the three set screws on the camera adapter Place the...

Страница 5: ...ove the handle loosen the front lens and the eyepiece The handle then will be adjustable for left or right hand use Take your time learning about your smart scope It will take practice to properly use...

Страница 6: ...icles can be cleaned following instructions in Cleaning Eyepiece section Q Screen becomes darker than in previous use S Replace batteries If the problem persists contact your dealer or other authorize...

Страница 7: ...articular purpose shall apply to the product All such implied warranties are hereby and expressly disclaimed LIMITATION OF LIABILITY ATN will not be liable for any claims actions suits proceedings cos...

Страница 8: ...den Ave Suite 1B South San Francisco CA 94080 phone 800 910 2862 650 875 0130 fax 650 875 0129 European Office phone 44 0 870 0111286 fax 44 0 845 3349142 The following countries can use our toll free...

Отзывы: