FOCUSING

To focus the Aries 258, first you will need to adjust the diopter. Simply turn the diopter clock-

wise until it stops. Then, while looking through the diopter at a subject, slowly turn the diopter 

back counter clockwise until the grain in the image is sharp.

NOTE: 

We suggest that you focus the diopter during daylight with the filter on. Next focus the 

front lens until the image and the grain are both sharp. When you are in low-light conditions and 

the daylight filter is off, you may focus the front lens to receive a sharp image, the diopter should 

not be adjusted.

NOTE:

 The front lens should be readjusted as you view objects at different distances.

CLEANING THE EYEPIECE

You may need to clean the eyepiece and of the unit you have purchased from time to time in 

order to guarantee top performance. When you receive your Aries 258 you should check for 

dust on the eyepiece of the unit.
Eyepiece is attached to the body of the unit by two small set screws. By loosening the set 

screws you can easily slide out the eyepiece section of the unit. If there is resistance when you 

slide out the eyepiece stop and make positive that the set screws are sufficiently loosened.

NOTE:

 You do not have to remove the set screws completely, they are very small and easy to 

misplace.

Now, with a little more effort in the same counter-clockwise direction, you can unscrew the 

eyepiece section of the scope.
Once the eyepiece section has been removed from your Aries scope, you may now clean the 

dust off the glass surfaces as well as the phosphor screen of the light intensifier tube. When 

reinserting the eyepiece into the scope, make sure it is seated completely with the internal 

rubber bushings.

CAUTION:

 Use only Photographic lens cleaning tissue on these surfaces. Be careful not to 

scratch or smudge any of these surfaces. When using compressed air to blow dust away, make 

sure to avoid inverting the can while spraying. This may cause frozen propellent to exit the can, 

which can result in serious problems of the glass and phosphor screen.

other situations with strong lighting may result in a temporary decrease of the proximity sensor’s 

performance.

LOW BATTERY INDICATOR

A Low battery indicator is another feature that is 

programmed into your “Smart” scope. If the bat-

teries start losing voltage. 

Led “B“

 will start to 

pulse. It Is time to change your batteries.

Led 

“R”

Led “

B

Led

 “I”

Содержание Aries MK

Страница 1: ...AMERICAN TECHNOLOGIES NETWORK CORP u s e r s g u i d e Aries Mk 258...

Страница 2: ...ies that may appear in this book 2001 ATN Corp All right reserved Master power switch Proximity sensor Manual focus Internal windage and elevation Infra red illuminator Control panel Mounts to standar...

Страница 3: ...ontrol box light up Make sure to keep both eyes open and we suggest that you use your right eye for aiming through the scope This will give you a HUD Heads Up Display of the scope s functions while us...

Страница 4: ...ess of the reticle and magnitude of the IR The sleep mode works in the following way The scope will automatically shut down if it dose not sense any activity for 20 minutes Activity includes pressing...

Страница 5: ...lide out the eyepiece stop and make positive that the set screws are sufficiently loosened NOTE You do not have to remove the set screws completely they are very small and easy to misplace Now with a...

Страница 6: ...the Aries scope entire mounting mechanism Tighten vertical fixator screws and horizontal fixator screws 5 Remount Aries 258 and tighten receptor attachment screws NOTE Receptor attachment screws may n...

Страница 7: ...r Video camera s lens or your 35 mm camera s lens Loosen the three set screws on the camera adapter Place the camera adapter over the Aries Mk 258 s eyepiece Tighten the three set screws to fit snugly...

Страница 8: ...certain that the pro tective glass surface of the sensor is always clean When the scope is first powered up the initial settings are Light intensifier tube Brightness 100 Reticle brightness 50 Illumi...

Страница 9: ...e turn the unit off and wait 1 2 minutes before turning the unit back on Adverse atmospheric conditions such as fog smog or haze and a lack of ambient light moon or starlight may diminish the effectiv...

Страница 10: ...de Video 35mm camera adaptable Superb multi coated 6 element lens system Manufactured exclusively by ATN Two year warranty SPECIFICATIONS Magnification 4 0x Intensifier Tube First gen hight res Lens S...

Страница 11: ...articular purpose shall apply to the product All such implied warranties are hereby and expressly disclaimed LIMITATION OF LIABILITY ATN will not be liable for any claims actions suits proceedings cos...

Страница 12: ...den Ave Suite 1B South San Francisco CA 94080 phone 800 910 2862 650 875 0130 fax 650 875 0129 European Office phone 44 0 870 0111286 fax 44 0 845 3349142 The following countries can use our toll free...

Отзывы: