background image

8

Informational Display Screens 

Dew Point Screen

The Dew Point Screen displays the dew point outside 
and inside the crawlspace.

Temperature Screen

The Temperature Screen displays the temperature 
outside and inside the crawlspace. 

The ATMOX system evaluates the outside and inside temperature 
to determine whether or not to ventilate the crawlspace. If the 
temperatures are too cold or too hot based on several calculations, 
the system will not ventilate with outside air. The ATMOX system 
automatically adjusts its temperature parameters for different times of 
the year. 

Note: If the outside sensor is located in direct sunlight, it will often 
heat the metal housing causing the sensor to read a temperature that 
is higher than the ambient outdoor temperature.  The overall outside 
moisture calculations (dew point) will not be incorrect, so this generally 
does not affect basic operation of the ATMOX system in determining 
when fans should be running.   

Dew point is the key to the ATMOX system. Dew point is calculated 
from the temperature and humidity measurements and gives you the 
best indicator of moisture in the air. A higher dew point means there 
is more moisture in the air, and a lower dew point means there is less 
moisture in the air.  The ATMOX system does not activate ventilation 
on an absolute number but instead uses a comparison of air in the 
two locations. Under most circumstances, the fans will ventilate when 
the outside dew point is 1 to 1.5 degrees lower than inside dew point.  
There are some exceptions to this built into the software, for example 
temperature parameters need to be met. There is also a time delay 
of 15 to 30 minutes to conserve energy and avoid constant on and 
off.  This means that you will not always see instantaneous change in 
operations.  

Содержание FLEX System

Страница 1: ...User s Guide ATMOX FLEX System Moisture Control System for Crawlspaces ...

Страница 2: ...ts please refer to an ATMOX Installation Manual Uses powerful yet quiet fans Creates cross circulation of air flow Ventilates only when beneficial Addresses odor issues Energy efficient uses less than 150 watts of power Option to incorporate a dehumidifier Fully automatic once installed KEY BENEFITS WHY ATMOX Issue 2018 03 Copyright 2018 ATMOX INC ...

Страница 3: ...lculates dew point inside and outside your crawlspace to determine when the fans or dehumidifier should run The fans allow for natural air circulation into the crawlspace An optional dehumidifier if equipped is only used when the system cannot find good air from the outside making the system energy efficient and environmentally friendly Once installed the ATMOX System will operate on its own and a...

Страница 4: ...on for your home and crawlspace The system is preset to the proper settings It is very rare for adjustments to be necessary If you have inadvertently made changes by pressing buttons talk to your installer about setting system back to its default settings Do not adjust the settings on your system without talking to your installer Improper settings can negatively affect the operation of the ATMOX s...

Страница 5: ...dity Sensor Standard System Components Product Specifications Usage Variable from 1 5 150 W Input Voltage 85 132V AC Output Voltage 12 13V DC Output Current Range 0 12 5A Data Input 2 Temperature RH Power Output 3 Switched 1 Constant Use only approved ATMOX Fans and Accessories with the ATMOX FLEX System ...

Страница 6: ...neficial or when inside relative humidity is elevated Runs with Red Output and with Yellow Output YELLOW OUTPUT Fans or dehumidifiers will run when the outside air is not beneficial and inside relative humidity is elevated PURPLE OUTPUT A constant power source for accessories RED OUTPUT Fans will run when the outside air is beneficial ...

Страница 7: ...ATMOX model and the installed software version To view all screens you can wait and watch as it scrolls automatically For faster rotation of screens you can manually change the display Press the M Button on the panel to scroll through each of the screens The M Button will also light up the screen for easier viewing Note The system will continue to auto rotate even while the M Button is being press...

Страница 8: ...re calculations dew point will not be incorrect so this generally does not affect basic operation of the ATMOX system in determining when fans should be running Dew point is the key to the ATMOX system Dew point is calculated from the temperature and humidity measurements and gives you the best indicator of moisture in the air A higher dew point means there is more moisture in the air and a lower ...

Страница 9: ...efault settings if the crawlspace humidity exceeds 80 and outside dry air is not beneficial then the controller will activate the Orange and Yellow outputs used for internal fans and an optional dehumidifier Once activated the fans and or dehumidifier will continue operation until the inside relative humidity is below 75 or when outside air is drier Your system will automatically trigger these out...

Страница 10: ...lert on the system Check screen to identify the reason for alarm MANUAL Under normal automatic operation this light is not illuminated If the Manual light was accidentally illuminated it can be turned off by pressing the bottom Arrow button one time to turn off ATMOX FLEX System ...

Страница 11: ... via low voltage 12v DC power Each color represents an output for a different function of the system Color coded plugs connect the low voltage wire to the Controller Data Transmission Light There is a small light on the Controller If the light is flashing quickly then data is not being received If the light is pulsing slowly then data is being transmitted or received ...

Страница 12: ...mation System notifications are designed to alert you of a potential problem The following are all possible alerts Communications Error There is a data connection problem with the wire inside the controller If you see this screen on your system contact your installer or ATMOX for more information Humidity Too High Under the system default settings this humidity alarm setting is turned to the off p...

Страница 13: ...o the crawlspace below a set temperature setting It is raining outside and the fans are running What is wrong The answer is probably nothing You have to trust the system even when it doesn t seem intuitive The fans will be activated by dew point and not humidity levels If a cold front comes through even with rain it is possible that the colder air will have a lower dew point than what is in the cr...

Страница 14: ...uch as mulch or pine needles from blocking ventilation The ATMOX display does not give a notification if any single or group of fans are not operating Fans should periodically be checked for operation Moisture Management vs Water Management It is important to note that the ATMOX system is a moisture management system and not a water management system Dry air or a dehumidifier cannot get rid of sta...

Страница 15: ...ng mold insects termites water rot electrical HVAC roof framing foundation floors drywall gutters ice dams or other problems that may occur in a house structure The warranty does not include any costs of removal or reinstallation Third party products by other manufacturers sold by ATMOX such as dehumidifiers are not covered by this warranty but may be covered under separate warranties by the produ...

Страница 16: ...Operating Principle ATMOX INC 10612 D Providence Road 229 Charlotte NC 28277 Phone 704 248 2858 Fax 704 675 9858 Email info atmox com Website www atmox com ...