DESCRIPTION OF THE APPLIANCE
2.1
General
The Atmos InterCombi wall-mounted gas boiler is a balanced flue
appliance, designed for delivering heat to the water of a CH system and
the domestic hot water.
The air supply and flue discharge can be connected to the appliance by
means of two separate pipes. A concentric connection can be delivered
upon request. The appliance has been inspected together with the
Atmos combination lead-through, but the appliance can also be
connected to combination terminals that comply with the universal test
requirements for combination terminals and that have a gas certification.
The appliance can also be fitted to an optional mounting bracket, a
frame with top connection and various connecting sets. These are
supplied separately.
The Atmos InterCombi wall-mounted gas boiler has the CE quality mark
and the Gas certification labels HE (Sedbuck A), SV , NZ (Solar
compatible) and CW Class 5 (Hot water performance rating 1 to 6,
where 6 is the highest) and IP44.
It is possible to use the appliance for hot water or for heating only. The
system that is not used does not need to be connected.
The appliance as delivered is suitable for natural gas (G20). A
conversion kit for propane (G31) can supplied upon request.
2.2
Operation
The Atmos InterCombi wall-mounted gas heater is a modulating high
efficiency boiler. This implies that the power is adjusted to the heat
demand.
In the aluminium heat exchanger two separate copper circuits have been
integrated.
Because of the separated circuits for central heating and hot water, the
heating and the hot water supply can operate independently of each
other. The hot water supply has priority over the heating. They cannot
work simultaneously.
The appliance has been provided with an electronic burner controller
that controls the fan with each heat demand from the heating system or
the hot water supply, opens the gas valve and ignites the burner and
continuously monitors the flame and controls it dependent on the power
required.
2.3
Operating conditions
A code indicates the operating condition of the appliance on the service
display of the operating panel.
-
Off
The appliance is not operating, but there is electrical power. There is no
response to any demand for hot domestic hot water or CH water. The
frost protection is active though. This means that the pump starts
running and the heat exchanger is heated when the temperature of the
water present here drops below 4 °C. When the frost protection is
activated, code
7
appears (heating of the heat exchanger).