Atmos EasySolar Installation Instructions Evacuated Tube Collector
16
Once the frame and the roof hooks have been fixed to the roof the header can be fitted to
the frame.
It is important that the header is fitted level, so that the water in the header drains
back correctly.
•
Use an angle grinder to cut a section out of a roof tile.
•
Cut two pieces of wakaflex each 50cm long.
•
Use a hollow punch to make two 20mm holes in one of the two pieces of Wakaflex.
Fix the pipe gland to the holes. If the correct size hollow punch is not available it is
possible to use a 22mm compression ring instead.
•
Place the wakaflex with the pipe gland over the tile with the section cut out and
underneath the tile higher up. Do not stick the wakaflex down till after the red and blue
collector pipes have been taken through the pipe gland.
•
Place the second piece of wakaflex on top and above the first piece and underneath
the tiles higher up.