Operation manual - EN
EN
www.atmos.cz
EN - 33
ALARM SETTINGS
-
DOPLNIT PELETY
poorly adjusted output of the
burner which has the effect of
low temperature of combustion
products
lack of pellets in the fuel reser-
voir (limit state)
Increase the burner output
by changing the T4 and T6
parameters, add pellets
Add pellets
Switch off and on the main
switch (red) to remove alarm
ALARM PELLETS
-
DOPLNIT PELETY
lack of pellets in the fuel reser-
voir
Add pellets
Switch off and on the main
switch (red) to remove alarm
33. Spare parts
Thermometer
/15/
(code:
S0041)
1
Main
switch
(red)
/16/
(code:
S0092)
1
Burner
switch
(black)
/16/
(code:
S0102)
1
Control (regulating) thermostat /17/ (code: S0021)
1
Safety
thermostat
/19/
(code:
S0068)
1
Fuse
T6,3A/1500-typ
H
/20/
(code:
S0200)
1
Door sealing cord, 18 x 18 /7/ (code: S0240)
1
Sibral gasket under the pellet burner (with an opening) /9/ (code: S0164)
1
Flue brake for the tube heat exchanger (code: P0482)
3
Exhaust
fan
/22/
(code:
S0131) 1
Capacitor for the exhaust fan - 1µF (code: S0171)
1
Impeller of exhasut fan Ø 150 mm (code: S0141)
1
Replacing the door sealing cord
Procedure: Use a screwdriver to remove the old cord and clean the groove where it was seated.
Use a hammer to slightly shape the cord from the square cross-section to the trapezoidal cross-section.
Grip the cord and impress it along the perimeter of the door (with the narrower base to the groove) to
make it sit in the groove (you can use a small hammer as an auxiliary tool). Grip the door decorative
nut in the open position and then repeatedly slowly slam the door until the cord is pressed in the
groove and the door can be closed. Finally, adjust the position of the wheel where the cam of the
closure gets engaged. Only using this procedure you can guarantee tightness of the door!