Technical Information
Model Guide - kW Output
2
Model
*Wattage Voltage Amperage Phase
Circuit breaker
size
Required wire
size
AT900-03
3 kW
110
27
1
30
10 AWG
AT900-04
3.8 kW
240
16
1
20
12 AWG
AT900-06
6.5 kW
240
27
1
30
10 AWG
AT900-08
8.5 kW
240
36
1
40
6 AWG
AT900-10
10.5 kW
240
44
1
50
6 AWG
AT900-13
13 kW
240
55
1
60
4 AWG
Minimum water flow to activate unit: 0.5 GPM
Nominal water volume: 0.11 gal (0.42l)
Working pressure: 0.5 -8 bar (7 -115 psi)
Tested pressure: 16 bar (230 psi)
Water connections: 1/2" NPT
Dimensions (in) (H x W x D): 7.3 x 11.8 x 3.55
Weight (Ib): 3.4
Model
240V
208V
110V
120V
AT900-04
3.8 kW
2.8 kW
-
-
AT900-06
6.5 kW
4.9 kW
-
-
AT900-08
8.5 kW
6.4 kW
-
-
AT900-10
10.5 kW
7.9 kW
-
-
AT900-13
13.0 kW
9.8 kW
-
-
AT900-03
-
-
3.0 kW
3.5 kW
* Wattage based on maximum voltage.