4
0364J–PLD–7/05
ATF16V8B/BQ/BQL
Note:
1. Not more than one output at a time should be shorted. Duration of short circuit test should not exceed 30 sec.
4.1
DC Characteristics
Symbol
Parameter
Condition
Min
Typ
Max
Units
I
IL
Input or I/O Low
Leakage Current
0
≤
V
IN
≤
V
IL
(Max)
-35
-100
µA
I
IH
Input or I/O High
Leakage Current
3.5
≤
V
IN
≤
V
CC
10
µA
I
CC
Power Supply
Current, Standby
V
CC
= Max,
V
IN
= Max,
Outputs Open
B-10
Com.
55
85
mA
Ind.
55
95
mA
B-15
Com.
50
75
mA
B-15
Ind.
50
80
mA
BQ-10
Com.
35
55
mA
BQL-15
Com.
5
10
mA
BQL-15
Ind.
5
15
mA
I
CC2
Clocked Power
Supply Current
V
CC
= Max,
Outputs Open,
f = 15 MHz
B-10
Com.
60
90
mA
Ind.
60
100
mA
B-15
Com.
55
85
mA
B-15
Ind.
55
95
mA
BQ-10
Com.
40
55
mA
BQL-15
Com.
20
35
mA
BQL-15
Ind.
20
40
mA
I
Output Short
Circuit Current
V
OUT
= 0.5 V
-130
mA
V
IL
Input Low Voltage
-0.5
0.8
V
V
IH
Input High Voltage
2.0
V
CC
+0.75
V
V
OL
Output High Voltage
V
IN
= V
IH
or V
IL
,
V
CC
= Min
I
OL
= -24 mA
Com., Ind.
0.5
V
V
OH
Output High Voltage
V
IN
= V
IH
or V
IL
,
V
CC
= Min
I
OH
= -4.0 mA
2.4
V
Содержание ATF16V8B
Страница 11: ...11 0364J PLD 7 05 ATF16V8B BQ BQL Figure 11 3 Registered Mode Logic Diagram ...
Страница 13: ...13 0364J PLD 7 05 ATF16V8B BQ BQL Figure 11 5 Complex Mode Logic Diagram ...
Страница 15: ...15 0364J PLD 7 05 ATF16V8B BQ BQL Figure 11 7 Simple Mode Logic Diagram ...
Страница 18: ...18 0364J PLD 7 05 ATF16V8B BQ BQL ...