![Atmel AT91SAM9261-EK Скачать руководство пользователя страница 23](http://html1.mh-extra.com/html/atmel/at91sam9261-ek/at91sam9261-ek_user-manual_3003441023.webp)
AT91SAM9261-EK Evaluation Board User Guide
4-1
6198C–ATARM–15-Dec-06
Section 4
Configuration Straps
4.1
Configuration
Straps
Table 4-1 gives details on configuration straps on the AT91SAM9261-EK evaluation
board and their default settings.
Table 4-1. Configuration Jumpers and Straps
Designation
Default
Setting
Feature
J2
Closed
3.3V Jumper
This jumper footprint is provided for 3.3V power consumption
measurement use. By default, it is closed. To use this feature,
the user has to open the strap by cutting it before soldering a
jumper.
J3
Closed
Forces power on. To use the software shutdown control, J3
must be opened.
J4
Opened
Enables Boot on the internal ROM
Closed
Enables Boot on the NCS0
J8
Closed
VDDPLL Jumper
J9
2-3
VDDBU Jumper select
1-2 : Lithium 3V Battery
2-3 : 1.2V from VDDCORE
J12
Closed
VDDCORE Jumper
J21
1-2
NPCS0 select
1-2: DataFlash device (MN7)
2-3: DataFlash card interface (J22)
Warning: In this case NPCS03 must be configured as
input.
S2
Opened
Disables the ICE NTRST input
S3
Closed
Enables the ICE RTCK return. S6 must be opened
S4
Closed
Enables the ICE NRST input
S5
Opened
Selects ICE mode or JTAG mode (See Section 6, Errata )
S6
Opened
Disables TCK <-> RTCK local loop. If S6 is closed, S3 must be
opened.
Содержание AT91SAM9261-EK
Страница 1: ...AT91SAM9261 EK Evaluation Board User Guide...
Страница 2: ...AT91SAM9261 EK Evaluation Board User Guide 6198C ATARM 15 Dec 06...
Страница 22: ...Board Description 3 10 AT91SAM9261 EK Evaluation Board User Guide 6198C ATARM 15 Dec 06...
Страница 32: ...Schematics 5 2 AT91SAM9261 EK Evaluation Board User Guide 6198C ATARM 15 Dec 06...
Страница 34: ...Errata 6 2 AT91SAM9261 EK Evaluation Board User Guide 6198C ATARM 15 Dec 06...
Страница 36: ...Revision History 7 2 AT91SAM9261 EK Evaluation Board User Guide 6198C ATARM 15 Dec 06...