14
atlona.com
Toll free: 1-877-536-3976
Local: 1-408-962-0515
System Settings
Display Auto Power On - When enabled, the unit will send a programmed command to the
display to turn on after detecting an A/V signal
Display Auto Power Off - When enabled, the unit will send a command to the display to turn off
after not detecting an A/V signal
Lamp Cool Down Timer
(10-300)
- Used with a projector whose lamp cannot be turned on for up
to 5 minutes after being shut off. Match settings with lamp delay on projector
Auto Power off timer
(10-240)
- Sets the period of time between the loss of A/V signal and when
the “Display Off” command is sent
Note:
LED will blink red for the auto power off time period then go solid
Note:
All functionality remains, only the HDBaseT output is turned off
Display Warm Up Timer
(10-300)
- Sets the period of time after the display is turned on, that the
power button will be locked
Note:
LED will blink green for the warm up timer period and then stay solid
Note:
When timers are set to 0 seconds, they will disable the timers’ functions
Control Type - Select whether the display on/off commands are sent using RS-232, TCP/IP, or
CEC
Feedback Verify
On: If receiving no feedback, the product will send the command up to 4 times
Off: The command will only be sent once, whether feedback is received or not