30
atlona.com
Toll free: 1-877-536-3976
Local: 1-408-962-0515
SetCmd X[Y]
e.g.
SetCmd on[PWR ON]
SetCmd X[Y]
e.g.
SetCmd on[PWR ON]
Sets the RS-232 or IP command for the selected button or
function X= on, off, vol+, vol-, and mute Y= command
e.g.
Set the on command to send the command PWR ON
SetEnd X[Y]
e.g.
SetEnd off[CR-LF]
SetEnd X[Y]
e.g.
SetEnd off[CR-LF]
Sets the line termination for the chosen command
X= on, off, vol+, vol-, mute, fbkon, fbkoff, fbkmute
Y= None, CR, LF, CR-LF, Space, STX, ETX, and null
e.g.
Set the command off to have a carriage return and line feed
SetFbVerify X
e.g.
SetFbVerify on
SetFbVerify X
e.g.
SetFbVerify on
Verifies the device is receiving commands X= on, off, sta
e.g.
Sends command up to 4 times until feedback verifies
command was received with feedback
TrigCEC X
e.g.
TrigCEC on
TrigCEC X
e.g.
TrigCEC on
Triggers the stored CEC command to turn the display on
and off X= on, off
TrigRS X
e.g.
TrigRS vol+
TrigRS X
e.g.
TrigRS vol+
Triggers the RS-232 command from RS-232 or IP
X= on, off, vol+, vol-, and mute
TrigIP X
e.g.
TrigIP vol-
TrigIP X
e.g.
TrigIP vol-
Triggers the IP command from RS-232 or IP
X= on, off, vol+, vol-, and mute
CtlType X
e.g.
CtlType rs-232
CtlType X
e.g.
CtlType rs-232
Sets the control type X= ip, rs-232, cec
e.g.
Set the control type to RS-232
CliMode X
e.g.
CliMode non-login
CliMode X
e.g.
CliMode non-login
Sets the control device’s IP mode X= sta, login, non-login
e.g.
Sets the IP mode to non-login
CliUser X
e.g.
CliUser
CliUser X
e.g.
CliUser admin
Sets the IP username for login X= username, (blank)
e.g.
Display the IP username by leaving x blank
CliPass X
e.g.
CliPass AtlonA
CliPass X
e.g.
CliPass AtlonA
Sets the IP password for login X= password, (blank)
e.g.
Set the IP password to AtlonA
CliIPAddr X
e.g.
CliIPAddr sta
CliIPAddr X
e.g.
CliIPAddr 192.168.0.23
Sets the IP address of the controlled device X= ip, sta
e.g.
Display the IP address of the controlled device
CliPort X
e.g.
CliPort 24
CliPort X
e.g.
CliPort 24
Sets the IP port of the controlled device X= port, sta
e.g.
Set the IP port to 24
AutoDispOff X
AutoDispOff X
Enable or disable display auto off X= on, off, sta
AutoDispOn X
AutoDispOn X
Enable or disable display auto on X= on, off, sta
APwrOffTime X
APwrOffTime X
Sets how long after receiving no signal to trigger auto
display off X= 1-240, sta
ProjSWMode X
ProjSWMode X
Set delay time for the display on command to be sent
X= 0-300, sta
Note:
Match the timing to the projector’s delay settings
ProjWarmUpT X
ProjWarmUpT X
Set period of time after the display is turned on that the
power command will not send X= 0-300, sta
VolKeyOPT X
VolKeyOPT X
Set the control type/device the volume button sends out
X= 0-2
DispRS X
DispRS X
Sets the display command type to RS-232 X= on, off, sta
DispCEC X
DispCEC X
Sets the display command type to CEC X= on, off, sta
DispIP X
DispIP X
Sets the display command type to TCP/IP X= on, off, sta
RS232zoneX[Y]
RS232zoneX[Y]
RS232zoneX[Y], X: 1-3. Y is the command sent to the
HDBT [Y] is the command string sent to the display device
RS232paraX[Y]
RS232paraX[Y]
RS232paraX[baudrate,databit,parity,stopbit] X is 1-3. [Y] is
the parameter for RS232.
CSpara[Y]
CSpara[Y]
Set RS232 parameter [Y] is the parameter for RS-232.
OSD X Y
OSD X Y
OSD X=func/info Y=on/off/sta
Aspect Y
Aspect Y
Aspect Y=full, overscan, underscan, letterbox, panscan,
follow, sta
Sets video aspect function
0
HDVS
1
RS-232
2
IP
0
HDVS
1
RS-232
2
CEC
3
IP
Volume Key
Display Key
Each command is terminated with a carriage return.
Feedback is terminated with a carriage return and line feed.
Note:
If the command fails or is incorrect the feedback should be “Command FAILED”