7
www.atlona.com
Toll free: 1-877-536-3976
Local: 1-408-962-0515
Dip Switch Settings
DS1
DS2
DS3
DS4
CAT5 Output Connection and EDID
0
0
0
0
Auto EDID and Copy EDID
1
0
0
0
Dual CAT5, 1080p, 2ch audio
1
0
0
1
Single CAT5, 1080p, 2ch audio
1
0
1
0
Dual CAT5, 1080p, 5.1ch audio
1
0
1
1
Single CAT5, 1080p, 5.1ch audio
1
1
0
0
Dual CAT5, 1080p, 7.1ch audio
1
1
0
1
Single CAT5, 1080p, 7.1ch audio
1
1
1
0
Dual CAT5, 1080i, 2ch audio
1
1
1
1
Single CAT5, 1080i, 2ch audio
C). Copy EDID: Please set the dip switch to “0000” (off). Make sure to power cycle the AT-PROHD85M-SR
after making this setting change on the dip switch. Turn off power and then back on to complete a power
cycle This function is used when you want a specific output and input to become associated. Select the out-
put dis¬play that you want to copy and then the source input. Next press and hold the previously selected
output and F/N button simultaneously for a couple of seconds then release. Characters on the LED display
will rotate in a circular pattern until process is complete. If EDID successfully copied the LED will display “M
OK”. If unsuc¬cessful it will display “M FL”. Repeat process for all desired input/output associations.
Note: If you wish to return the copied EDID back to the auto EDID functionality use the following steps. Step
1: Set the dip switch to 1-1-1-1(on), next power cycle the AT-PROHD85M-SR.
Step 2: Set the dip switch to 0-0-0-0(off), next power cycle the AT-PROHD85M-SR. All connected devices will
be reset to the lowest common denominator.
4. Connect supplied IR receiver and emitter cables to the AT-PROHD85M-SR
and supplied matrix receivers for IR functionality. Trans mitters need to be placed over IR window on device
to ensure successful functionality. IR receiver modules should be placed in line of sight for handheld control-
ler to successfully extend IR commands.
Note: When connecting IR receivers and IR emitters be extremely careful to insert them into the correct port.
Failure to do so will cause damage to the switch, receiver or burn out the IR eye.