![ATLASIO SHD+ Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/atlasio/shd/shd_assembly-instruction-manual_3002401014.webp)
14
T R O U B L E S H O O T I N G
PROBLEM
ROOT CAUSE
CORRECTIVE ACTION
Display indicate E01
A motor line open
Press the up or down key again, it still exists,
please check the motor A connection line.
Display indicate E02
B motor line open
Press the up or down key again, it still exists,
please check the connection line of motor B.
Display indicate E03
A motor over current
Press the up or down key again, it still exists, please refer to
a professional and replace motor A or reduce the load.
Display indicate E04
B motor over current
Press the up or down key again, it still exists, please refer to
a professional and replace motor B or reduce the load.
Display indicate E05
A motor hall fault
Press the up or down key again, it still exists, please check
the connection or refer to a professional to replace motor A.
Display indicate E06
B motor hall fault
Press the up or down key again, it still exists, please check
the connection or refer to a professional to replace motor B.
Display indicate E07
Abnormal main power supply
Cannot be eliminated after power off, replace the power supply.
Display indicate E08
A motor current abnormality
Cannot be eliminated after power off and need to return to the factory.
Display indicate E09
B abnormal motor current
Cannot eliminate the need to return to the factory after power off.
Display indicate E10
A motor power device is broken
It cannot be eliminated after power off
and it needs to be returned to the factory.
Display indicate E11
B motor power device is broken
It cannot be eliminated after power off
and it needs to be returned to the factory.
Display indicate E12
Abnormal learning position
Relearning position.
Display indicate E13
Over temperature protection
Wait for temperature to drop.
Display indicate E14
A motor is blocked
Press up or down again, it still exists, please refer to
a professional and replace motor A or reduce the load.
Display indicate E15
B motor block
Press the up or down key again, it still exists, please refer to
a professional and replace motor B or reduce the load.
Display indicate E16
Position imbalance
Restore factory mode.
Display indicate E17
Key data loss
Return to factory for processing.
T R O U B L E S H O O T I N G
When a failure occurs, please refer to the following solutions, find out the presumable causes
and solve the problem, if these are of no help, please refer to a professional.
PROBLEM
PROBLEM CAUSE
REMEDY
No power display
Power plug not inserted properly.
There is no power in the socket.
The power is not switched on.
The jack must be electrical.
Press the plug.
Turn on the power.
No wireless charging
Power not connected.
Mobile device does not have wireless
charging function.
Check power is connected and on.
Check your mobile device has wireless
charging capability.
Содержание SHD+
Страница 16: ...w w w a t l a s i o d e...