background image

 AtlasSound.com 

– 4 – 

Owner’s Manual

PA40G / PA60G

Commercial Amplifiers

1601 Jack McKay Blvd. • Ennis, Texas 75119  U.S.A.

Telephone: 800.876.3333 • Fax: 800.765.3435

 

When The Device Is In Use

  

 

•  To prevent electric shock, do not remove the product cover as there are high voltage components inside. Refer all servicing to  
 

Atlas Sound. 

•  Should any of the following irregularities occur during use, immediately switch off the power, disconnect the power cord from the  
 

AC outlet and contact Atlas Sound. Do not to attempt to continue operation with the product as this may cause fire or electric shock:

 

•  Smoke or strange smell coming from the unit.

 

•  If the product falls or the case is damaged.

 

•  If water or any metallic objects falls into the product.

 

•   If the power supply cord is damaged in any way.

 

•  If the unit is malfunctioning.

• 

Do not insert or drop metallic objects or flammable materials into the ventilation holes of the product's cover, as this may result in  

 

electric shock or fire.

• 

Do not place any containers with liquid or metallic objects on the top of the product. If any liquid spills into the unit, fire or electric  

 

shock may result.

• 

Never operate this product or touch the power supply cord during an electrical storm, electric shock may result.

• 

Never exceed the power rating on the product when connecting equipment. Fire and/or property damage may result. 

• 

Operate the product only with the voltage specified on the unit. Fire and/or electric shock may result if a higher voltage is used. 

• 

Do not modify, kink, or cut the power cord. Do not place the power cord in close proximity to heaters and do not place heavy objects  

 

on the power cord, including the product itself, doing so may result in fire or electrical shock. 

• 

Ensure that the safety ground terminal is connected to a proper ground. Never connect the ground to a gas pipe as a catastrophic  

 

disaster may result. 

• 

Be sure the installation of the product is stable, avoid slanted surfaces as the product may fall and cause    

 

 

 

injury or property damage.

 

When Installing The Product

 

•   Plugging in or unplugging the power cord with wet hands may result in electric shock. 
•  Never move the unit with the power cord plugged into the wall, as damage to the power cord may result.  
•  When unplugging the cord from the wall, grasp the plug, NOT the cord. 
•  Never install this product in humid or dusty locations, nor in direct sunlight, near sources of heat, or in areas where sooty smoke or  
 

steam are present. Fire and electric shock may result.

•  Keep all sides of the unit at least 3

1

2

" away from objects that may obstruct air flow to prevent the unit's internal temperature rise.

 

When The Product Is In Use

 

•  Never place heavy objects on the product, causing it to fall and/or break, resulting in personal injury and property damage. In    
 

addition, the product itself may fall and cause injury and property damage. 

•  Contact Atlas Sound for instructions on cleaning the inside of the unit. Large accumulations of dust inside the unit may result in heat  
 

buildup and fire. 

•  Ensure that the power supply plug is securely plugged into the wall outlet. Never allow dust to accumulate on the power plug or  
 

inside the wall outlet. 

•  When cleaning the unit or the unit is not to be operated for an extended period, unplug the power cord from the wall.

CAUTION 

WARNING

CAUTION 

Содержание PA40G

Страница 1: ...t In Right In 100V 240V 50Hz 60Hz 750mA Balanced Input Summed Inputs 1601 Jack McKay Blvd Ennis TX 75119 800 876 3333 AtlasSound com Power Limit Signal PA40G Front Silkscreen Artwork 40 Watts 70 7V 10...

Страница 2: ...876 3333 Fax 800 765 3435 Table of Contents Important Safety Instructions 3 Introduction 5 Key Features 5 Applications 5 Front Panel Description 6 Rear Panel Description 7 Wiring the PA40G PA60G 7 Opt...

Страница 3: ...ripod bracket or table specified by the manufacturer or sold with the apparatus When a cart is used use caution when moving the cart apparatus combination to avoid injury from tip over 13 Unplug this...

Страница 4: ...power cord in close proximity to heaters and do not place heavy objects on the power cord including the product itself doing so may result in fire or electrical shock Ensure that the safety ground ter...

Страница 5: ...stallation personnel require to meet or exceed their customer s expectations Small and compact and engineered for reliability the Atlas Sound PA40G PA60G will provide years of service and flexibility...

Страница 6: ...or turn the input gain down until the LED is no longer illuminated Refer to Limit LED Load Conditions for more information 3 Signal Indicator When the signal LED illuminates this indicates that input...

Страница 7: ...r damage may occur It is recommended to use class 3 rated 16 gauge wire or higher for speaker wiring 4 Global IEC AC Mains Power Receptacle The PA Models support global power sources from 100V 240V 50...

Страница 8: ...nated steady state it means the speaker system load to the amp is lower than what the amp is rated This usually is detected when the system is first set up Below are a few load conditions to check for...

Страница 9: ...t going to MCM Electronics Parts Express or search the internet for Audio Impedance Meter Measuring 70 7V or 100V Distributed Speaker Systems Large distributed systems typically utilize 70 7V North Am...

Страница 10: ...utput Sensitivity Line Input 500mv 600 Inputs 2 3 RCA 500mv 10k Output Regulation Less Than 2dB No Load To Full Load Signal To Noise Ratio Balanced Input 55dB Unbalanced RCA Summed 55dB Power Requirem...

Страница 11: ...tlasSound com Specifications are subject to change without notice Owner s Manual PA40G PA60G Commercial Amplifiers 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 876 3333 Fax 800 765 3435...

Страница 12: ...rns must comply with our returns policy set forth below When products returned to Atlas Sound do not qualify for repair or replacement under our warranty repairs may be performed at prevailing costs f...

Отзывы: