NO.
A
B
Description
Terminal
Cable
diameter
Length
Anderson/SC25-8
Anderson
25mm²
25mm²
1-3m
1-3m
Used for connection between
battery and inverter
For battery parallel
connection
4.2
Communication line connection
4.2.1
RJ45 Communication point definition(8P8C)
1 2 3 4 5 6 7 8
PIN
1
2
3
4
5
6
7
8
RS485
CAN
RS485_A
NC
GND
NC
NC
CANL
NC
CANH
GND
NC
RS485_A
GND
RS485_B
NC
RS485_B
NC
4.2.2
RJ11 Communication point definition(6P6C)
1 2 3 4 5 6
PIN
1
2
3
4
5
6
RS485
NC
TX
RX
GND
NC
NC
Explanation
◆
RS232 communication: BMS can communicate with the upper computer through
RS232 interface, so that it can monitor various information
of the battery through the upper computer, including
battery voltage, current, temperature, status and battery
production information.
◆
RS485 / can communication: can communication, used for inverter communication.
◆
RS485 communication: With dual RS485 interfaces, you can view the information
of the pack. If it is necessary to communicate with the
monitoring equipment through RS485, the monitoring
equipment, as the host, polls the data according to the address,
and the address setting range is 1 ~ 15.