Failure Modes
Hard Alarms
: The following give a constant audible alarm. If present, the solenoid valve is closed,
and the 4-20, Volt free and ethernet module transmit the alarm.
Lamp Failure
UV Sensor Failure
Soft Alarm
s: The following remaining errors give a 15 second audible chirp only
Solenoid Module
Failure
4-20mA Module
Failure
Volt Free module
failure
Ethernet module
Failure
Boil Water Advisory
: If any failure occurs on an Atlas UV system, the water
must not be used for human consumption until the system is returned to a
safe operational mode. If the water is used for human consumption during this
period, the water must be boiled (minimum 20 minutes at a full boil)
prior to
consumption.
QR Codes
A
QR code
(Quick Response code) is a matrix barcode first designed
for the automotive industry. Atlas uses the QR code to store a link to
a specific page on our website. Users with a camera phone equipped
with the correct reader application can scan the image of the QR
code and over a wireless network connect to a Atlas web page in the
phone’s browser. Atlas’ QR webpage has information on how to pur-
chase replacement components as well as a helpful video directory on
system servicing (i.e. How to change a UV lamp or quartz sleeve). To
access the QR code on the Atlas controller, press the control button
twice and the QR code screen will appear as follows: