Atlas User Manual: Diesels
with QSI Sound
21/52
13 January 2015
Decoders (Quantum, Quantum Titan, or
Quantum Titan with ET)
Table 1 (cont.) - Analog Programming Options
Program
Option #’s
(POPs)
Option Name
(default setting)
Message when
Entering Option
Option Description
7
Notch V-Max
(14 volts)
“Notch V-Max
equals X”
Sets Track Voltage for highest Diesel Notch sounds
8
V-Start
(8.5v)
“V-Start equals X”
Sets track voltage where locomotive will leave Neutral. (See the V-Start Example
below.)
9
V-Max
(12v)
“V-Max equals X”
Sets track voltage where full power is applied to motor. (See the V-Max Example
below.)
10
Throttle Mode
(RTC)
“Throttle Mode
equals X””
Selects between Standard Throttle Control (STC) and Regulated Throttle Control
(RTC).
11
Programming Reset
“Warning – about to
reset”
After next
Quick
or
Slow
Operation, three Bell rings followed by a spoken “Reset” to
indicate locomotive returned to factory default parameter values.
12
About
“Model number”
Each
Quick
or
Slow
Operation provides progressive information about Quantum
software model number, software version, and software release date.
13
Horn Volume
“Volume equals X”
Customizes Horn Volume (16 levels). Max is 15.
14
Bell Volume
“Volume equals X”
Customizes Bell Volume (16 levels). Max is 15.
15
Prime Mover 1 Volume
“Volume equals X”
Customizes Prime Mover 1 Volume. (16 levels). Max is 15.
16
Vents and Cooling Fan
Volume
“Volume equals X”
Customizes Vents and Cooling Fans Volume (16 levels). Max is 15.
17-19
Reserved
“Reserved”
20
Air Brakes Volume
“Volume equals X”
Customizes Air Brake Air Release Volume (16 levels). Max is 15.
21
Alternate Horn Volume
Customizes Alternate Horn Volume. (16 levels). Max is 15.
22
Prime Mover 2 Volume
Customizes Prime Mover 2 Volume. (16 levels). Max is 15 with Prime Mover 1 Volume
in background for comparison
23-25
Reserved
“Reserved”
26
Pump Volume
“Volume equals X”
Customizes Air Pump Volume (16 levels). Max is 15.
27
Air Let-off Volume
“Volume equals X”
Customizes Long Air Release Volume (16 levels). Max is 15.
28
Short Air Let-off Volume
“Volume equals X”
Customizes Short Air Let-off Volume (16 levels). Max is 15.
29
Reserved
“Reserved”
30
Flange Volume
“Volume equals X”
Customizes Flange/Squealing Brake Volume (16 levels). Max is 15.
31
Dynamic Brake Fan
Volume
“Volume equals X”
Customizes Dynamic Brake Cooling Fan Volume (16 levels). Max is 15.
32
Coupler Volume
“Volume equals X”
Customizes All Coupler Sound Volumes (16 levels). Max is 15.
33
Reserved
“Reserved”
3.13.1 Entering Analog Programming
Use this sequence of actions to enter analog programming using the direction switch:
•
Apply power and turn up the throttle to hear the sound system come on.
•
Within five seconds of powering up, turn on the
Bell
with a
Quick
flip-and-back
operation.
•
Within three seconds of the Bell turning on, turn the
Bell
off with a second
Quick
flip-and back
operation.
•
Within three seconds, turn the
Bell
back on again with a third
Quick
flip-and-back
operation.
Note:
If you delay too long after power has been first applied, the opportunity to enter programming will time
out, and you will need to start again by shutting off and reapplying track power
.
Once you perform the three Bell operations after applying power, the Bell will shut off automatically; you will hear
“
Enter Programming
;”