Atlas DSP2210 Скачать руководство пользователя страница 8

 AtlasSound.com 

– 8 – 

Specifications are subject to change without notice.

Owner’s Manual

DSP2210 & 

DSP2212

Digital Processor  

and Amplifier

1601 Jack McKay Blvd. • Ennis, Texas 75119  U.S.A.

Telephone: 800.876.3333 • Fax: 800.765.3435

AC POWER INPUT (120VAC @ 60Hz or 240VAC @ 50Hz)

As noted in the ‘Important Notices’, DSP2210/DSP2212 utilize a UL recognized IEC AC power plug and cord (provided with the unit) 
which must not be changed or defeated.  Please follow these important instructions. Failure to do so will void the product warranties.

The Mains Plug is the main disconnect device for the product, and shall be located so as to be readily accessible.

NOTE: Once the AC power is switched ‘ON’ it will take approximately ‘30’ seconds to initialize and start up.

•   Do not defeat the safety purpose of polarized, keyed or grounding type connectors. A polarized plug has two (or multiple) contacts 

with one wider or longer than the other. A grounding type plug has two blades and a third grounding plug.  The wide blade or third 
prongs are provided for your safety. Do not defeat or change these.  If the provided IEC power plug does not fit into your outlet, 
consult an electrician or your local authority having jurisdiction to replace the outlet to insure meeting local building codes while 
assuring proper connection

•  Protect the power cord from being walked on or pinched particularly at the plug, receptacle outlet, and the exit point of the unit

70V SPEAKER TERMINATION

Phoenix connectors are used and are keyed or polarized to fit one way, do not force fit these connectors and follow these basic instructions;

•  Do NOT force fit the connectors – they are polarized to fit in one direction

•  Follow the +/- wiring polarity for all speakers

•  Use only 70V speakers 

•  Ensure that total speaker wattage taps per channel does NOT EXCEED 80% of the rated output 25W RMS per zone.

Amp Outputs (70V)

50W RMS / ZONE

70V SPEAKERS

+

+

120VAC

Power

AC cable with IEC plug provided. All 

wiring to meet NEC/ UL code

Replace AC Fuse with UL 

recognized 2A @ 250VAC or 

5A @ 110VAC

Fuse

(2A @ 250V AC)

or

(5A @ 150V AC)

Typical view of 

UL rated Fuse

AC POWER IN

Содержание DSP2210

Страница 1: ...Specifications are subject to change without notice Owner s Manual DSP2210 DSP2212 Digital Processor and Amplifier 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 876 3333 Fax 800 765 3435...

Страница 2: ...ms or when unused for long periods of time 14 Refer all servicing to qualified service personnel Servicing is required when the device has been damaged in any way such as power supply cord or plug is...

Страница 3: ...the ventilation holes of the device s cover as this may result in electric shock or fire Do not place any containers with liquid or metallic objects on the top of the device If any liquid spills into...

Страница 4: ...wing basic masking capabilities Create An Acceptable Level of Speech Privacy In Open Work Areas Enhance Speech Privacy Between Modular Offices Decrease Intelligibility and Noise Distraction Caused By...

Страница 5: ...tary Encoder LCD Display Noise Filter Graphic EQ Graphic EQ Mixer 1 Lynx SMS AVIO Core I O Processor A D D A 70V Line 1 70V Line 2 Mic CC Lynx SMS AVIO Core Interface Processor Lynx SMS AVIO Core AVB...

Страница 6: ...10 DSP2212 Digital Processor and Amplifier 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 876 3333 Fax 800 765 3435 SYSTEM VIEWS DSP2210 FRONT PANEL DSP2212 FRONT PANEL DSP2210 REAR PANEL...

Страница 7: ...ual DSP2210 DSP2212 Digital Processor and Amplifier 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 876 3333 Fax 800 765 3435 INSTALLATION COMPUTER NETWORK TERMINATION DSP2212 only NOTE All...

Страница 8: ...es and a third grounding plug The wide blade or third prongs are provided for your safety Do not defeat or change these If the provided IEC power plug does not fit into your outlet consult an electric...

Страница 9: ...ther electronic equipment to insure proper thermal ventilation This unit may also be mounted on a shelf using the pads provided x4 START UP BOTH DSP2210 AND DSP2212 Needed equipment PC Based Computer...

Страница 10: ...UUT similar to the following screen DISCOVER UNITS Select the Settings screen from the Menu SYSTEM OVERVIEW SYSTEM HARDWARE SOFTWARE REQUIREMENTS The DSP2210 DSP2212 unit has the following hardware a...

Страница 11: ...Kay Blvd Ennis Texas 75119 U S A Telephone 800 876 3333 Fax 800 765 3435 Select the Unit and click the Connect to this unit button The Software should now be able to access and control the unit eg Sel...

Страница 12: ...1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 876 3333 Fax 800 765 3435 NOISE RAMP Select Noise Ramp Button On ramps the noise level 1dB every 10 seconds to its previous level after power...

Страница 13: ...2212 only Connect both the Computer running the Application Software and the unit RJ45 ports to the LAN ports on the Ethernet Router with DHCP Server Select the Settings screen from the Menu Click Dis...

Страница 14: ...rate audio conversion 48kHz D A converter type Audio 24 bit Sigma Delta D A performance dynamic range converter 100dB A weighted A D performance dynamic range 110dB A weighted Non volatile memory Mem...

Страница 15: ...zed UL94VO Electronic components RoHS Operating temperature 0 to 50 C Storage temperature 40 to 85 C Humidity 95 non condensing max TROUBLESHOOTING GUIDE 1 Read and review all sections and follow inst...

Страница 16: ...f purchase under the terms of this warranty All warranty returns must comply with our returns policy set forth below When products returned to Atlas Sound do not qualify for repair or replacement unde...

Отзывы: