AtlasSound.com
– 8 –
Specifications are subject to change without notice.
Owner’s Manual
AP-S20RT
AC Distribution & Suppressor Unit
1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.
Telephone: 800.876.3333 • Fax: 800.765.3435
Rear Panel Features
1. AC Mains Input
Connect the 14 Gauge 9' (3m) power cord to a 20A 120VAC outlet to provide power to the AP-S20RT.
2. AC Power Outlets
These six outlets are “Live” when the front panel power switch is activated. The two Unswitched Outlets are always live if the power
cord is connected to 120VAC.
3. XLR Light Socket
A 12VDC XLR light socket provides power for the optional AL-GNL18 light.
4. Light Socket Power Switch
Two-position switch to power On/Off the XLR light socket.
5. Remote Activation
There are two methods to remotely activate the AP-S20RT:
A. External Switch
- The Ext SW terminals are connected to a latching type dry contact closure to activate the
AP-S20RT.
Note:
The Remote Bypass switch must be shorted for Remote Activation. This feature can be used for
Emergency Power Down (EPD), when tied into a normally closed latching contact closure (e.g. Fire Panel).
B. DC Voltage
- When you apply 5V - 24VDC to the Ext SW terminals the unit will activate. See “Remote Activation
Drawings” for details.
The terminals marked “+12V” and “GND” can be connected to a remote panel LED (not included) to indicate function when remotely
activated.
1
2
3
4
5