Atlas AA30PHD Скачать руководство пользователя страница 9

 

– 9 – 

AtlasSound.com

Specifications are subject to change without notice.

Owner’s Manual

AA30PHD

30W Mixer Amplifier

1601 Jack McKay Blvd. • Ennis, Texas 75119  U.S.A.

Telephone: 800.876.3333 • Fax: 800.765.3435

Using the PHD Mixer Amplifier Diagnostic System 

The AAPHD Series features a patent pending Amplifier Self Diagnostic System. The PHD (Push Here Diagnostic) is simple to use and 
is very effective running a 70V distributed system diagnostic test to assure the amplifier has the proper load applied. The proper load 
will assure you a long lasting trouble free audio experience with your new AAPHD Series amplifier.  Many amplifiers fail because an 
incorrect load is applied to the amplifier. This is especially true when using the amplifier in a 25V or 70V distributed audio speaker 
system. There are a few common failure points that can occur during system installation that are listed below.

Common Amplifier Failure Conditions, also see “How to Trouble Shoot Your Speaker System if the Limit LED is Illuminating”.

 

1.  A short in the speaker wiring.

 

2.  Improper load selection or power tap setting on 70V speaker systems. It is very common when using many speakers to    

 

 

have one of the speakers tapped accidently at 8

Ω

. This error will definitely be very hard on a 70V amp and in most  

 

 

 

cases cause the amp to fail within a few days. This kind of error is easy to make, time consuming to find and costly to fix. 

 

3.  Too many speakers attached or the wrong power taps are selected. If a 100 watt amp is used in a 70V system and it has ten  

 

 

speakers all tapped at 10W, but three of the speakers are accidently tapped at 30W, that comes up to 160W of power  

 

 

 

required to drive the system properly. While it may work at low levels, as soon as the system needs to be louder the  

 

 

 

amp will be strained and could fail over time.

Most amplifier failures are caused by improper installation on the speaker side. There are two known ways to test the speaker system 
after everything is installed.
 

A.  Measure the speaker system using a true audio frequency impedance meter. These are the best way to see if your speaker  

 

 

system is wired correctly for the amplifier.

 

B.  Run the PHD Self Diagnostic test. 

Running a Self-Diagnostic Test using the PHD Feature 

Step 1

 - Install the AAPHD Mixer amplifier, connect the input signals. Turn all levels to minimum. Do not attach the speaker system to 

the amp at this point. 

Step 2

 - Install the 70V distributed speaker system per the design, double check speaker tap settings. The total power for all the 

speakers should NOT exceed the maximum power rating of the amplifier installed. 

Step 3

 - Connect the speaker system to the amplifier. Pay special attention when connecting the speaker leads to the proper terminals 

on the amplifier. 

Note:

 All speaker power taps must be on a 70V setting.

Step 4

 - Turn the amplifier On.

Step 5

 - Before starting the system Diagnostic test. Make sure no people are present or near the speakers during the diagnostic test 

without taking proper precautions. A 1 watt test tone will be present at each speaker. The audible SPL level will be based on the power 
tap setting at each speaker and sensitivity specification of the speaker. The audible SPL level may be alarming to some people. Wear 
proper hearing protection before starting the test.

Step 6

 - Activate the PHD circuit by inserting a small, pointed tool through the hole on the front panel labeled PHD. Press and hold 

the momentary switch for 5 seconds, then release. A test tone will be audible through the speaker system. If the Limit LED does not 
illuminate Yellow, the system is properly set up and no errors in the system were found. Continue the installation.

Note: During the initial start of the diagnostic test, the Limit indicator may flash Yellow for a few seconds until an accurate 
diagnostic reading has been completed, continue to hold the PHD switch in for 5 seconds to assure the test is complete. After 
5 seconds and the Limit indicator is illuminating Yellow steadily, stop and read the section “How to Trouble Shoot Your Speaker 
System If the Limit LED is Illuminating.

Содержание AA30PHD

Страница 1: ...com Specifications are subject to change without notice Owner s Manual AA30PHD 30W Mixer Amplifier 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 876 3333 Fax 800 765 3435 AA30PHD 30W Mix...

Страница 2: ...rtant Safety Instructions 3 Introduction 5 Key Features 5 Applications 5 Front Panel Description 6 Rear Panel Description 7 PHD Diagnostic System Test 9 Common Amplifier Failure Conditions 9 Trouble S...

Страница 3: ...plug is damaged liquid has been spilled or objects have fallen into the device the device has been exposed to rain or moisture does not operate normally or has been dropped 15 WARNING To reduce the r...

Страница 4: ...wer cord in close proximity to heaters and do not place heavy objects on the power cord including the product itself doing so may result in fire or electrical shock Ensure that the safety ground termi...

Страница 5: ...ered for reliability the Atlas Sound AA30PHD will provide years of service and flexibility in background music and paging applications Key Features 30W Into 25V 70 7V and 4 Loads Automated Diagnostic...

Страница 6: ...tem using the PHD feature for proper wiring and amplifier loading this LED will illuminate Yellow if a fault is sensed in the audio speaker system See Using the PHD Load Impedance Testing System Note...

Страница 7: ...nals To select between Mic or Line input levels refer to the DIP switch chart on the rear of the amplifier for feature assignment If connecting an unbalanced line level input tie short the G and termi...

Страница 8: ...function is ON or assigned to the feature stated DP SW 1 Zone 2 Assign Input 3 When ON Input 3 signal will be routed to the Zone 2 Output terminals The signal routed is PRE the front panel level cont...

Страница 9: ...stem after everything is installed A Measure the speaker system using a true audio frequency impedance meter These are the best way to see if your speaker system is wired correctly for the amplifier B...

Страница 10: ...t set to a 4 8 or 16 ohm setting If one speaker is set to one of these settings it will cause a fault condition A simple and quick way to test this besides visually looking at each speaker is to have...

Страница 11: ...f the diagnostic test the Limit indicator may flash Yellow for a few seconds until an accurate diagnostic reading has been completed continue to hold the PHD switch in for 5 seconds to assure the test...

Страница 12: ...Replace the knobs with security covers Atlas Sound part number AAVCC 5 available in quantities of 5 Front Panel Knob Security Cover or Signal Peak Limit Power PHD 3 5 6 4 3 2 1 9 0 10 8 7 2 5 6 4 3 2...

Страница 13: ...lasSound com Specifications are subject to change without notice Owner s Manual AA30PHD 30W Mixer Amplifier 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 876 3333 Fax 800 765 3435 Block D...

Страница 14: ...r 70V Distributed Systems Level Controls Inputs 1 3 Rear Panel Inputs Mic Line Balanced Qty 1 3 Position PHX Type 3 5mm Pitch Auxiliary Unbalanced Qty 2 RCA Tone Controls Bass 6dB 100Hz Treble 6dB 10k...

Страница 15: ...nput Sensitivity Impedance Input 1 Mic Mode 5mv No Trim 1200 Input 1 Line Mode 316mV 10dBV 1200 Input 2 3 316mV 10dBV 10k Signal To Noise Ratio Mic 55dB Line 55dB Telephone 55dB Input 2 3 75dB Phantom...

Страница 16: ...eturns must comply with our returns policy set forth below When products returned to Atlas Sound do not qualify for repair or replacement under our warranty repairs may be performed at prevailing cost...

Отзывы: