– 15 – AtlasSound.com

Specifications are subject to change without notice.

Owner’s Manual

AA200PHD-CE

200W Mixer Amplifier

1601 Jack McKay Blvd. • Ennis, Texas 75119  U.S.A.

Telephone: 800.876.3333 • Fax: 800.765.3435

Connecting a Remote Level Control with Remote Input Select (RIS)

Remote location of a level control can be accomplished via the Remote Level control port. You can control Input 2 or Inputs 4, 5, 
and 6. The AAPHD series remote level design is based on 10VDC return VCA type topology. Connections to a 10K pot require three 
conductors, with a minimum of 22 gauge wire, the 10K pot can be placed up to 1000ft away. The return ports can be paralleled together 
if one pot will control all inputs. Below are Illustrations on different ways to configure a remote level to the AAPHD Series amplifiers.

Example 1

 - Using a WPD-VC10K for remote level control.

AA200PHD-CE

AA200PHD-CE

Содержание AA200PHD

Страница 1: ...Specifications are subject to change without notice Owner s Manual AA200PHD CE 200W Mixer Amplifier 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 876 3333 Fax 800 765 3435 AA200PHD CE 200...

Страница 2: ...tant Safety Instructions 3 Introduction 5 Key Features 5 Applications 5 Front Panel Description 6 Rear Panel Description 7 PHD Diagnostic System Test 12 Common Amplifier Failure Conditions 12 Trouble...

Страница 3: ...or plug is damaged liquid has been spilled or objects have fallen into the device the device has been exposed to rain or moisture does not operate normally or has been dropped 15 WARNING To reduce the...

Страница 4: ...wer cord Do not place the power cord in close proximity to heaters and do not place heavy objects on the power cord including the product itself doing so may result in fire or electrical shock Ensure...

Страница 5: ...ide years of service and flexibility in today s background music and paging applications Key Features 200W Into 50V 100V and 4 Loads Automated Diagnostic System Test Push Here Diagnostic for 100V Dist...

Страница 6: ...ult Indicator When testing the system using the PHD feature for proper wiring and amplifier loading this LED will illuminate Yellow if a fault is sensed in the audio speaker system See Using the PHD L...

Страница 7: ...equencies by 6dB at 10kHz Rotating counter clockwise from the 12 00 position will decrease cut treble frequencies by 6dB at 10kHz 3 Input 1 Balanced Microphone or Line level signals connect to the and...

Страница 8: ...ntom Power 24VDC is active when Input 1 is set to Mic mode and the switch is in the ON position Note Only use this feature if you are using condenser microphones otherwise leave in the OFF position DP...

Страница 9: ...t section has a 3 position Phoenix connector for Mic or Line input signals and a 3 5mm stereo jack that is summed The level to the amplifier mix is controlled by Input 4 level located on the front pan...

Страница 10: ...e up position the function is OFF or assigned to the feature stated when a switch is in the down position the function is ON or assigned to the feature stated Switch B DP SW 1 Mute Receive Input 6 Whe...

Страница 11: ...vel Controls and PRE the Master Level on the front panel Set the system s maximum levels using the amplifier input level controls and then use the remote potentiometer as an attenuator from the maximu...

Страница 12: ...quency impedance meter These are the best way to see if your speaker system is wired correctly for the amplifier B Run the PHD Self Diagnostic test Running a Self DiagnosticTest using the PHD Feature...

Страница 13: ...speaker setting to make sure it is not set to a 4 8 or 16 ohm setting If one speaker is set to one of these settings it will cause a fault condition A simple and quick way to test this besides visual...

Страница 14: ...e connected to the amplifier The LED should not steadily illuminate if a proper load is applied Note An occasional LED flash is okay during standard operation When LED is ON audible distortion may be...

Страница 15: ...emote Level control port You can control Input 2 or Inputs 4 5 and 6 The AAPHD series remote level design is based on 10VDC return VCA type topology Connections to a 10K pot require three conductors w...

Страница 16: ...ce for remote selection of 3 inputs without running audio signal from the amplifier This is ideal because the result is clean audio with no chance of picking up interference It is intended to be used...

Страница 17: ...ch take the place of the front panel knobs After the amp has been installed and is operating as desired grasp the front panel knobs and pull straight out from the front panel Replace the knobs with se...

Страница 18: ...m 18 Specifications are subject to change without notice Owner s Manual AA200PHD CE 200W Mixer Amplifier 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 876 3333 Fax 800 765 3435 Block Diag...

Страница 19: ...s 1 6 Rear Panel Inputs Mic Line Balanced Qty 4 3 Position PHX Type 3 5mm Pitch Auxiliary Unbalanced Qty 2 RCA Auxiliary Unbalanced Qty 1 3 5mm Amp In Unbalanced RCA 600 Tone Controls Bass 6dB 100Hz T...

Страница 20: ...150 Technical Data Inputs Total Qty 6 Frequency Response 50Hz 15kHz 3dB Thd N 0 5 Or Less At 1kHz Rated Output Input Sensitivity Impedance Input 1 2 3 4 Mic Mode 5mv No Trim 1200 Input 1 2 3 4 Line Mo...

Страница 21: ...tlasSound com Specifications are subject to change without notice Owner s Manual AA200PHD CE 200W Mixer Amplifier 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 876 3333 Fax 800 765 3435 N...

Страница 22: ...sSound com 22 Specifications are subject to change without notice Owner s Manual AA200PHD CE 200W Mixer Amplifier 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 876 3333 Fax 800 765 3435 N...

Страница 23: ...tlasSound com Specifications are subject to change without notice Owner s Manual AA200PHD CE 200W Mixer Amplifier 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 876 3333 Fax 800 765 3435 N...

Страница 24: ...s warranty All warranty returns must comply with our returns policy set forth below When products returned to Atlas Sound do not qualify for repair or replacement under our warranty repairs may be per...

Отзывы: