Atlas AA120M Скачать руководство пользователя страница 22

 

Specifications are subject to change without notice

 AtlasSound.com

1601 JACK MCKAY BOULEVARD ENNIS, TEXAS 75119 U.S.A.   •    TELEPHONE: (800) 876-3333   •   FAX: (800) 765-3435

©2006 ATLAS SOUND LP 

Printed in U.S.A. 

   00106 

ATS002179 RevA 01/06 

PP 

OWNER'S MANUAL

AA120M MIXER AMPLIFIER

22

WIRING THE AAVCC-10K VCA POTENTIOMETER

 

Atlas Sound part number AAVCC-10K consists of a single gang "Decora" style wall plate with a pre-
mounted 10k potentiometer and knob.
Use two conductor unshielded wire connecting the pot terminals to the terminals marked "VCA" on the 
back of the amp.

 

RACK MOUNT KIT

For permanent mounting of the AA120M into equipment racks, order part number AARM-2RU. If multiple 
units are being rack mounted, install Atlas 1RU (SVP19-1-052) vented panels between amplifiers in order
to aid cooling.

Rack Ear Installation

To VCA Terminals

Содержание AA120M

Страница 1: ...U S A TELEPHONE 800 876 3333 FAX 800 765 3435 2006 ATLAS SOUND LP Printed in U S A 00106 ATS002179 RevA 01 06 PP OWNER S MANUAL AA120M MIXER AMPLIFIER AA120M Atlas Sound Mixer Amplifier Signal Power...

Страница 2: ...for future reference Do not install this device in dusty or humid locations or in direct exposure to sunlight In addition locations that have steam or sooty conditions are not to be used as this may r...

Страница 3: ...switchable Input 5 line level 1 Module Input Inputs 1 4 and 6 can send or receive mute commands 2 Mute Buses 1 VOX and 1 contact closure 1 Tape and 1 Line outputs Mute assignable internal relay 24VDC...

Страница 4: ...posed to water or other liquids which may result in fire or electric shock Operate the product only with the voltage specified on the unit Fire and or electric shock may result if a higher voltage is...

Страница 5: ...grasp the plug NOT the cord Never block the panel vents in the product s cover Heat buildup may result inside the unit and fire may result Never install this product in humid or dusty locations nor i...

Страница 6: ...s condition is normal 5 Master Gain Control The MASTER GAIN CONTROL will raise or lower all the input channels together A good starting point for setting gain structure is to set MASTER GAIN CONTROL a...

Страница 7: ...te control port affects only the level of INPUT 5 Dipswitch 3 PHANTOM When set to the OFF position PHANTOM POWER is turned off on INPUTS 1 4 When set to the ON position PHANTOM POWER 24VDC is availabl...

Страница 8: ...le for CD DVD line level outputs When set to the Mic position Input 1 sensitivity is suitable for microphone input 10 Input 1 Balanced mic or line level signals connect to the and G terminals Refer to...

Страница 9: ...el control 12 Mute Sens For Vox Mute Bus This control adjusts how sensitive the mute send circuitry on INPUT 1 2 3 4 or 6 reacts Setting the control fully counter clockwise will lower the sensitivity...

Страница 10: ...Out Line level mono signals are available at this jack for connection to recording devices The signal available here is PRE tone control and low cut filter and comes from the internal mix bus 21 Line...

Страница 11: ...two points together via an external contact closure These two points must be connected to send or receive any signal By connecting the Bridge In Out terminals of two AA120M a simple room combining sys...

Страница 12: ...ts 5 and 6 are set to be PRE input mute assignment Example Input 5 will commonly have a CD player inserted into to it for background and or MOH The CD s signal is fed to the amplifier output for backg...

Страница 13: ...tup section for typical wiring diagrams COM Speaker common or negative connection 8 OHM Connect to direct coupled loudspeakers 25V Connect to transformer coupled 25V loudspeakers with a total load imp...

Страница 14: ...Vox Mute Input 5 Level Zone 3 Level Zone 2 10 0 10 0 10 0 10 0 10 0 10 0 10 0 G G G G Unswitched Outlet 120V AC 60Hz Max 500W Outlet Breaker 125V AC 4A Push Reset 120V AC 60Hz 300W 100V 70V 25V 8 Com...

Страница 15: ...evel balance Dipswitch 6 allows you to select between a 100mV or 300mV input sensitivity Connect Zone 3 output to the MOH input on your telephone system Adjust Input 5 s Zone 3 output level as needed...

Страница 16: ...for proper level balance Dipswitch 6 allows you to select between a 100mV or 300mV input sensitivity Connect the external level controls to the 70V speaker output Dipswitch Settings Dipswitch 1 OFF D...

Страница 17: ...front panel input level control is turned down Adjust INPUT 6 Zone 2 Level as needed Connect the Chime Speaker to Zone 2 output terminals Dipswitch Settings Dipswitch 1 OFF Dipswitch 2 OFF Not affect...

Страница 18: ...e AS ML is a mic or line input module with VCA capabilities Another volume control AAVCC 10K has been wired into the VCA terminals on the MODULE This control will vary the BGM ONLY Dipswitch Settings...

Страница 19: ...Bridge terminals of both amplifiers are connected together through a DPST switch that makes combines or breaks separates the Bridge connections between the amplifiers When the switch is closed any au...

Страница 20: ...rim Input 3 Trim Input 2 Trim Input 1 Trim Input 5 Zone3 Zone2 Mute 10 10 0 10 10 0 10 10 0 10 10 0 10 10 0 10 10 0 10 10 0 Bypass Send Rcv Send Bypass Rcv Send Off Rcv Zone2 Level 10 0 0 10 Zone3 Lev...

Страница 21: ...nced signals connect the G to the terminal Unbalanced Inputs and Outputs Pre made RCA cables can be purchased from vendors to simplify interconnection to external devices Zone 2 Out Use 2 conductor 20...

Страница 22: ...as Sound part number AAVCC 10K consists of a single gang Decora style wall plate with a pre mounted 10k potentiometer and knob Use two conductor unshielded wire connecting the pot terminals to the ter...

Страница 23: ...r need assistance with your specific application contact Atlas Sound Tech Support at 1 800 876 3333 WARNING ZONE 2 ZONE 3 MUTE CC INPUT 2 INPUT 3 INPUT 4 INPUT 5 INPUT 6 MAIN PCB RCV VOX MUTE R524 C62...

Страница 24: ...EVEL CHANNEL 4 IN 4 LEVEL LINE PHANTOM MIC PRE TRIM ZONE 2 LEVEL MUTE 3 PRE MUTE POST MUTE CH 4 MUTE SWITCH CH 4 INTERNAL JUMPERS ZONE LEVEL CHANNEL 5 IN 5 LEVEL PRE ZONE 2 LEVEL MUTE 3 PRE MUTE POST...

Страница 25: ...Hz 20kHz 3dB DISTORTION 1 at rated power SENSITIVITY Input 1 Line 316mV 10dBV 10k Ohm Mic 316mV 3 16mV 50dBV 70dBV Inputs 2 4 Line 100mV 20dBV 10k Ohm Mic 316mV 3 16mV 50dBV 70dBV Input 5 Line 316mV 1...

Страница 26: ...e without notice AtlasSound com 1601 JACK MCKAY BOULEVARD ENNIS TEXAS 75119 U S A TELEPHONE 800 876 3333 FAX 800 765 3435 2006 ATLAS SOUND LP Printed in U S A 00106 ATS002179 RevA 01 06 PP OWNER S MAN...

Страница 27: ...e without notice AtlasSound com 1601 JACK MCKAY BOULEVARD ENNIS TEXAS 75119 U S A TELEPHONE 800 876 3333 FAX 800 765 3435 2006 ATLAS SOUND LP Printed in U S A 00106 ATS002179 RevA 01 06 PP OWNER S MAN...

Страница 28: ...r installed in other than a workman like manner The original sales invoice should be retained as evidence of purchase under the terms of this warranty All warranty returns must comply with our returns...