Owner’s Manual

AA100PHD

100W Mixer Amplifier

1601 Jack McKay Blvd. • Ennis, Texas 75119  U.S.A.

Telephone: 800.876.3333 • Fax: 800.765.3435

 

When The Device Is In Use

  

 

•  To prevent electric shock, do not remove the product cover as there are high voltage components inside. Refer all servicing to  
 

Atlas Sound. 

•  Should any of the following irregularities occur during use, immediately switch off the power, disconnect the power cord from the  
 

AC outlet and contact Atlas Sound. Do not to attempt to continue operation with the product as this may cause fire or electric shock:

 

•  Smoke or strange smell coming from the unit.

 

•  If the product falls or the case is damaged.

 

•  If water or any metallic objects falls into the product.

 

•   If the power supply cord is damaged in any way.

 

•  If the unit is malfunctioning.

• 

Do not insert or drop metallic objects or flammable materials into the ventilation holes of the product's cover, as this may result in  

 

electric shock or fire.

• 

Do not place any containers with liquid or metallic objects on the top of the product. If any liquid spills into the unit, fire or electric  

 

shock may result.

• 

Never operate this product or touch the power supply cord during an electrical storm, electric shock may result.

• 

Never exceed the power rating on the product when connecting equipment. Fire and/or property damage may result. 

• 

Operate the product only with the voltage specified on the unit. Fire and/or electric shock may result if a higher voltage is used. 

• 

Do not modify, kink, or cut the power cord. Do not place the power cord in close proximity to heaters and do not place heavy objects  

 

on the power cord, including the product itself, doing so may result in fire or electrical shock. 

• 

Ensure that the safety ground terminal is connected to a proper ground. Never connect the ground to a gas pipe as a catastrophic  

 

disaster may result. 

• 

Be sure the installation of the product is stable, avoid slanted surfaces as the product may fall and cause    

 

 

 

injury or property damage.

 

When Installing The Product

 

•   Plugging in or unplugging the power cord with wet hands may result in electric shock. 
•  Never move the unit with the power cord plugged into the wall, as damage to the power cord may result.  
•  When unplugging the cord from the wall, grasp the plug, NOT the cord. 
•  Never install this product in humid or dusty locations, nor in direct sunlight, near sources of heat, or in areas where sooty smoke or  
 

steam are present. Fire and electric shock may result.

•  Keep all sides of the unit at least 3

1

/

2

" away from objects that may obstruct air flow to prevent the unit's internal temperature rise.

 

When The Product Is In Use

 

•  Never place heavy objects on the product, causing it to fall and/or break, resulting in personal injury and property damage. In    
 

addition, the product itself may fall and cause injury and property damage. 

•  Contact Atlas Sound for instructions on cleaning the inside of the unit. Large accumulations of dust inside the unit may result in heat  
 

buildup and fire. 

•  Ensure that the power supply plug is securely plugged into the wall outlet. Never allow dust to accumulate on the power plug or  
 

inside the wall outlet. 

•  When cleaning the unit or the unit is not to be operated for an extended period, unplug the power cord from the wall.

CAUTION 

WARNING

CAUTION 

Содержание AA100PHD

Страница 1: ...om Specifications are subject to change without notice Owner s Manual AA100PHD 100W Mixer Amplifier 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 876 3333 Fax 800 765 3435 AA100PHD 100W M...

Страница 2: ...3 Introduction 5 Key Features 5 Applications 5 Front Panel Description 6 Rear Panel Description 7 PHD Diagnostic System Test 11 Common Amplifier Failure Conditions 11 Trouble Shooting the Fault LED 12...

Страница 3: ...r plug is damaged liquid has been spilled or objects have fallen into the device the device has been exposed to rain or moisture does not operate normally or has been dropped 15 WARNING To reduce the...

Страница 4: ...ower cord in close proximity to heaters and do not place heavy objects on the power cord including the product itself doing so may result in fire or electrical shock Ensure that the safety ground term...

Страница 5: ...provide years of service and flexibility in background music and paging applications Key Features 100W Into 25V 70 7V and 4 Loads Automated Diagnostic System Test Push Here Diagnostic for 70V Distribu...

Страница 6: ...tem using the PHD feature for proper wiring and amplifier loading this LED will illuminate Yellow if a fault is sensed in the audio speaker system See Using the PHD Load Impedance Testing System Note...

Страница 7: ...unter clockwise from the 12 00 position will decrease cut bass frequencies to a maximum of 6dB at 100Hz 2 Treble Control Normally set at the 12 00 position rotating clockwise will increase boost trebl...

Страница 8: ...s connection is usually done via remote switch on a microphone 8 VOX Mute Sensitivity Control Input 1 signal can be used to trigger or activate a mute command When an input is set to Mute Receive via...

Страница 9: ...or converting the AAPHD into a slave amp When a line level signal is connected to this input the internal connection between the preamp and internal power amp is broken Audio signals applied to this c...

Страница 10: ...IC position Input 1 will accept microphone level signals when in the Line position Input 1 will accept line level or telephone signals DP SW 8 RIS Remote Input Select activates the RIS terminals when...

Страница 11: ...pedance meter These are the best way to see if your speaker system is wired correctly for the amplifier B Run the PHD Self Diagnostic test Running a Self DiagnosticTest using the PHD Feature Step 1 In...

Страница 12: ...set to a 4 8 or 16 ohm setting If one speaker is set to one of these settings it will cause a fault condition A simple and quick way to test this besides visually looking at each speaker is to have a...

Страница 13: ...connected to the amplifier The LED should not steadily illuminate if a proper load is applied Note An occasional LED flash is okay during standard operation When LED is ON audible distortion may be he...

Страница 14: ...rol port You can control Input 1 or Inputs 2 3 and 4 The AAPHD series remote level design is based on 10VDC return VCA type topology Connections to a 10K pot require three conductors with a minimum of...

Страница 15: ...AA30PHD features a unique interface for remote selection of 3 inputs without running audio signal from the amplifier This is ideal because the result is clean audio with no chance of picking up inter...

Страница 16: ...lifiers optional security covers are available which take the place of the front panel knobs After the amp has been installed and is operating as desired grasp the front panel knobs and pull straight...

Страница 17: ...asSound com Specifications are subject to change without notice Owner s Manual AA100PHD 100W Mixer Amplifier 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 876 3333 Fax 800 765 3435 Block...

Страница 18: ...Master Inputs 2 4 Rear Panel Inputs Mic Line Balanced Qty 2 3 Position PHX Type 3 5mm Pitch Auxiliary Unbalanced Qty 2 RCA Auxiliary Unbalanced Qty 1 3 5mm Amp In Unbalanced RCA 600 Tone Controls Bas...

Страница 19: ...A Unbalanced 150 Technical Data Inputs Total Qty 4 Frequency Response 80Hz 15kHz 3dB Thd N 1 or Less at 1kHz Rated Output Input Sensitivity Impedance Input 1 2 Mic Mode 5mv No Trim 1200 Input 1 2 Line...

Страница 20: ...eturns must comply with our returns policy set forth below When products returned to Atlas Sound do not qualify for repair or replacement under our warranty repairs may be performed at prevailing cost...

Отзывы: