– 1 –
AtlasSound.com
Specifications are subject to change without notice.
Owner’s Manual
AA100PHD
100W Mixer Amplifier
1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.
Telephone: 800.876.3333 • Fax: 800.765.3435
Страница 1: ...om Specifications are subject to change without notice Owner s Manual AA100PHD 100W Mixer Amplifier 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 876 3333 Fax 800 765 3435 AA100PHD 100W M...
Страница 2: ...3 Introduction 5 Key Features 5 Applications 5 Front Panel Description 6 Rear Panel Description 7 PHD Diagnostic System Test 11 Common Amplifier Failure Conditions 11 Trouble Shooting the Fault LED 12...
Страница 3: ...r plug is damaged liquid has been spilled or objects have fallen into the device the device has been exposed to rain or moisture does not operate normally or has been dropped 15 WARNING To reduce the...
Страница 4: ...ower cord in close proximity to heaters and do not place heavy objects on the power cord including the product itself doing so may result in fire or electrical shock Ensure that the safety ground term...
Страница 5: ...provide years of service and flexibility in background music and paging applications Key Features 100W Into 25V 70 7V and 4 Loads Automated Diagnostic System Test Push Here Diagnostic for 70V Distribu...
Страница 6: ...tem using the PHD feature for proper wiring and amplifier loading this LED will illuminate Yellow if a fault is sensed in the audio speaker system See Using the PHD Load Impedance Testing System Note...
Страница 7: ...unter clockwise from the 12 00 position will decrease cut bass frequencies to a maximum of 6dB at 100Hz 2 Treble Control Normally set at the 12 00 position rotating clockwise will increase boost trebl...
Страница 8: ...s connection is usually done via remote switch on a microphone 8 VOX Mute Sensitivity Control Input 1 signal can be used to trigger or activate a mute command When an input is set to Mute Receive via...
Страница 9: ...or converting the AAPHD into a slave amp When a line level signal is connected to this input the internal connection between the preamp and internal power amp is broken Audio signals applied to this c...
Страница 10: ...IC position Input 1 will accept microphone level signals when in the Line position Input 1 will accept line level or telephone signals DP SW 8 RIS Remote Input Select activates the RIS terminals when...
Страница 11: ...pedance meter These are the best way to see if your speaker system is wired correctly for the amplifier B Run the PHD Self Diagnostic test Running a Self DiagnosticTest using the PHD Feature Step 1 In...
Страница 12: ...set to a 4 8 or 16 ohm setting If one speaker is set to one of these settings it will cause a fault condition A simple and quick way to test this besides visually looking at each speaker is to have a...
Страница 13: ...connected to the amplifier The LED should not steadily illuminate if a proper load is applied Note An occasional LED flash is okay during standard operation When LED is ON audible distortion may be he...
Страница 14: ...rol port You can control Input 1 or Inputs 2 3 and 4 The AAPHD series remote level design is based on 10VDC return VCA type topology Connections to a 10K pot require three conductors with a minimum of...
Страница 15: ...AA30PHD features a unique interface for remote selection of 3 inputs without running audio signal from the amplifier This is ideal because the result is clean audio with no chance of picking up inter...
Страница 16: ...lifiers optional security covers are available which take the place of the front panel knobs After the amp has been installed and is operating as desired grasp the front panel knobs and pull straight...
Страница 17: ...asSound com Specifications are subject to change without notice Owner s Manual AA100PHD 100W Mixer Amplifier 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 876 3333 Fax 800 765 3435 Block...
Страница 18: ...Master Inputs 2 4 Rear Panel Inputs Mic Line Balanced Qty 2 3 Position PHX Type 3 5mm Pitch Auxiliary Unbalanced Qty 2 RCA Auxiliary Unbalanced Qty 1 3 5mm Amp In Unbalanced RCA 600 Tone Controls Bas...
Страница 19: ...A Unbalanced 150 Technical Data Inputs Total Qty 4 Frequency Response 80Hz 15kHz 3dB Thd N 1 or Less at 1kHz Rated Output Input Sensitivity Impedance Input 1 2 Mic Mode 5mv No Trim 1200 Input 1 2 Line...
Страница 20: ...eturns must comply with our returns policy set forth below When products returned to Atlas Sound do not qualify for repair or replacement under our warranty repairs may be performed at prevailing cost...