Wiring the DA-22SYS

1.  Loosen the 4 screws and remove the cover plate. (Figure 4)

2.  There are two knockout sizes available, 

1

/

2

" and 

3

/

4

", for electrical cable access. (Figure 5)

3.  Insert the electrical cable retainer. Refer to local codes for low voltage wiring regulations. (Figure 6)

4.  Determine if the DA-22SYS will be used as a single stand-alone speaker or used with a secondary 8-ohm speaker of similar acoustical    

 

 

characteristics as the DA-22SYS. One-channel or two-channel operation mode configuration is done in the AtlasIED Discover software. 

Note:

 The    

 

Secondary Parallel Speaker Output has the same EQ settings as the DA-22SYS but does have separate level control. If configured to 1 Channel  

 

 

mode, the DA-22SYS will get the full power of the amp up to 20W on a PoE+ switch. If configured to 2 Channel mode, the DA-22SYS will receive    

 

10W of power and the Secondary Parallel speaker will receive 10W on a PoE+ switch.

Wiring the DA-22SYS to Single Channel Mode

Amplifier Configuration

 - The DA-22SYS UI amplifier ships preconfigured for 1 CH (Speaker) Mode allowing for the full PoE / PoE+ power to be 

delivered to the speaker. 

Ethernet Connection

 - Run a plenum rated Ethernet Cat5e/6 cable through the cable retainer as shown below. 

Note:

 Do not overtighten the Cat5e/6 

cable retainer or damage may occur to the conductors. Connect the opposite end of the Ethernet cable to a LAN PoE / PoE+ switch. No other wiring is  
required. Refer to local electrical codes for low voltage wire types.

Wiring the DA-22SYS to Dual Channel Mode

Amplifier Configuration

 - The DA-22SYS ships (default) preconfigured for Single Channel Mode. To configure the DA-22SYS to power and control a 

second speaker, go into the amplifier UI settings, and change the amplifier operation mode from Single Channel Mode to Dual Channel Mode.  

Note:

 The secondary speaker impedance needs to be 8-ohm or greater. The secondary speaker or Ch 2 Output has the same EQ settings as the 

DA-22SYS but does have separate level control. When Dual Channel Mode is selected, the primary speaker will receive 50% of the PoE / PoE+ power 
and the secondary speaker or Ch 2 amplifier output will receive the remaining 50% of the power.

Secondary  Speaker Wiring

 - Run a 16-18 gauge 2-conductor plenum rated speaker wire from the second speaker to the DA-22SYS. Refer to local 

electrical codes for low voltage wire types. Run the speaker wire through the cable retainer as shown below.

Wiring the Secondary Speaker to the CH 2 Amplifier Terminals

 - Connect the wire to the CH 2 amplifier output connector, paying attention to the 

wiring polarity. Tighten the connections securely but do not force. Refer to the picture below for connection and location to the amplifier secondary 
output terminals.

Figure 4

Figure 5

Figure 6

Figure 7

Содержание DA-22SYS

Страница 1: ...e to drive a second passive speaker of the same type When the DA 22SYS amplifier is configured to Dual mode the amplifier power is split between the DA 22SYS and the 8 ohm passive speaker The secondar...

Страница 2: ...ftware can be downloaded using the following link http autoupdate atlasied com atlasieddiscover setup exe To access AtlasIED IP speakers a username and password is required for login Factory assign Us...

Страница 3: ...r 1 CH Speaker Mode allowing for the full PoE PoE power to be delivered to the speaker Ethernet Connection Run a plenum rated Ethernet Cat5e 6 cable through the cable retainer as shown below Note Do n...

Страница 4: ...8 ohm speaker and if it is a 70V speaker select the 8 ohm tap The wiring illustration below shows the DA 22SYS amplifier s secondary output wired to an AtlasIED DT22T 8 ohm power tap 5 Run a plenum r...

Страница 5: ...ve owners No endorsement is implied Due to continual product development specifications are subject to change without notice ATS007063 RevA 6 22 AtlasIED com TELEPHONE 800 876 3333 SUPPORT ATLASIED CO...

Страница 6: ...ces into an Ethernet switch and connecting a computer to the network All Dante devices are automatically discovered and displayed in Dante Controller so a system can be up and running in seconds To do...

Страница 7: ...refully Heed all warnings Assure that the speaker is securely mounted Always assure amplifier power is off before making any connections Keep instructions for future reference Should any questions ari...

Страница 8: ...ansducer Qty and Size 1 8 203mm HF Transducer Qty and Size 1 1 26mm HF Crossover Frequency 2 800Hz First Order Cone Material Curvilinear Treated Industrial Paper Sensitivity 98dB SPL Average Driver Pr...

Страница 9: ...twork Ethernet IEEE 802 3 10 100Base T PoE PoE IEEE 802 3 AF AT Compliant Protocols IP Addressing DHCP Static Auto Registration Dante Controller AtlasIED Discovery Control Software Digital Audio Audin...

Страница 10: ...abor unless there is included with the returned product s a written request for an estimate of repair costs before any nonwarranty work is performed In the event of replacement or upon completion of r...

Отзывы: