CAUTION
CAUTION
NEVER INSERT THE DRAIN LINE DIRECTLY
INTO A DRAIN, SEWER LINE, OR TRAP.
ALWAYS ALLOW AN AIR GAP BETWEEN
THE DRAIN LINE AND THE WASTE WATER.
THIS WILL PREVENT THE POSSIBILITY OF
SEWAGE BEING BACK-SIPHONED INTO
THE CONDITIONER.
THE WASTE CONNECTION OR DRAIN
OUTLET SHALL BE DESIGHED AND
CONSTRUCTED TO PROVIDE AN
AIR-GAP TO THE SANITARY WASTE
SYSTEM OF 2 PIPE DIAMETERS OR
1 INCH(25MM). ( WHICHEVER IS
LARGER)
TOOLS REQUIRED FOR INSTALLATION:
Two adjustable wrenches.
Additional tools may be required if modifications to home plumbing are required.
Use copper, brass, or PEX pipe and fittings.
Some codes may also allow PVC plastic pipe. Refer to local codes.
Always install the included bypass valve, or 3 shut-off valves. Bypass valves let you turn
off water to the softener for repairs, but still have water in the house pipes.
5/8” OD drain line is needed for the drain.
CAUTION
NOTE
PERFORM ALL PLUMBING ACCORDING TO LOCAL PLUMBING CODES.
16
Water Pipe Inlet
Water Pipe Outlet
Brine Elbow
Assembly
Brine Valve
Connector
Detail
Pressure Tank
Cabinet
Optional
Pipes Fixed
Structure
Floor Drain
100V-120V / 220-240V
AC 50/60Hz
Drain Elbow
Assembl
5/8” Drain Line
Laundry Drain