OILTRONIX FAILURE
Manually locking the valve (temporary
solution)
Disconnect the connector (1) of the stepper motor, to
ensure that the stepper motor does not try to rotate the
valve.
Rotate the white coupling of the valve manually until
the blind hole (2) in the coupling is in line with the
threaded hole (3) in the housing.
Block the valve by screwing a bolt (M5 x 20) through
the housing and in the blind hole in the coupling.
HEATER
Problem: Heater does not start when switched on.
Problem: Flame extinghuises.
Problem: Heater shuts off.
Problem: Control unit locked.
Possible faults
Corrective actions
No fuel.
Check fuel level.
Fuse blown.
Check fuse.
Bad electrical contact.
Check electrical wiring.
Blocked air duct or exhaust gas duct.
Check combustion air duct and exhaust gas duct.
Glow plug defective.
Replace glow plug.
Fan motor defective.
Replace fan motor.
Possible faults
Corrective actions
Overheating
Cool down and start again.
Possible faults
Corrective actions
Upper or lower voltage limit is reached.
Check power.
Possible faults
Corrective actions
Device switched off and on again too many
times.
Contact your agent.
Check the correct position of the blind
hole with a
∅
4 mm pin.
Contact Atlas Copco for a thorough scan
and repair.
(1)
(3)
(2)
Содержание XRVS 1350
Страница 2: ......
Страница 24: ... 24 FLOW DIAGRAM EXHAUST AFTERTREATMENT HPFP DOC EAM DPF ...
Страница 28: ... 28 SH3 ENGINE CIRCUIT 1 2 3 5 6 7 8 9 G 4 10 A B C D E F 3 A 3 B 3 D 3 C 3 E 3 G 3 H 3 I 3 F 9822 0963 68 ...
Страница 30: ... 30 SH4 COMPRESSOR CIRCUIT 9822 0963 68 ...
Страница 31: ... 31 SH5 COMPRESSOR CONTROL MODULE 5 A Reference Name 5 A Customer Remote Installation 9822 0963 68 ...
Страница 34: ... 34 SH7 OPTIONAL EQUIPMENT 7 A 7 B 9822 0963 68 Reference Name 7 A Preheater Arctic 7 B Oiltronix ...
Страница 133: ... 133 Maintenance Log Compressor Customer Serial number Service hours Maintenance action Date By initials ...
Страница 135: ......
Страница 136: ......