- 40 -
Air Discharge Temperature Control parameter
“Enable”
When the parameter is enable or enable lock, the PID
will regulate the Air Discharge Temperature to the
Air Discharge Temperature Setting.
After starting the compressor, the CCM will first run
through the Temperature Control Warmup procedure
in the Warmup status. This procedure will override
the standard Warmup procedure and settings.
When the engine started, the CCM executes
following Warmup procedure if the Air Discharge
Control Parameter is Enable (lock);
If the Coolant Water Temperature is at 50
°
C or above,
the Warmup procedure is ended.
When the Warmup procedure has ended, the CCM
can go to the Not Loaded status, or to the Load/
Unload status.
5.3.3.16Barometric Calibration
For applications running in low barometric pressure
environments (high altitude), Cummins compensates
the diesel injection.
5.4
Operation via User Interface
5.4.1
General
In this section an overview is given of all statuses of
the CCM.
The reactions of the compressor to actions of the
operator and to signals from the compressor itself, are
also shown.
5.4.2
Ready for Start status
5.4.2.1 Manual start
Other actions and signals have no effect in this status.
A: action (carried out by operator)
S: signal (generated by compressor)
R: reaction
S Warnings
R Are shown on the screen
A Emergency stop button
R To emergency stop status
(see section 5.4.13)
A
↓
-button, press once
R Set pressure - 0.1 bar
A
↑
-button, press once
R Set pr 0.1 bar
A
↓
-button, press
continuously
R Set pressure - 0.1 bar/
second
A
↑
-button, press
continuously
R Set pr 0.1 bar/
second
A Power OFF switch
R End of operation
A System info button
R To system info status
(see section 5.4.14)
A Start command
R To permissive start status
(see section 5.4.4)
Содержание PTS 1600 Cud S3A/T3 APP
Страница 1: ...Instruction Manual for Portable Compressors English PTS 1600 Cud S3A T3 APP QSX15 ...
Страница 2: ......
Страница 89: ... 89 Circuit diagrams ...
Страница 97: ... 97 ...
Страница 103: ... 103 ...
Страница 115: ... 115 ...
Страница 123: ... 123 ...
Страница 126: ... 126 ...
Страница 127: ......
Страница 128: ...Printed in Belgium 12 2013 2954 7430 01 ...