- 63 -
– Reassemble in reverse order of dismantling.
– Inspect and tighten all air intake connections.
– Reset the air filter vacuum indicator by pushing
the reset button (8).
6.4.2.4 Cleaning the filter element
– Withdraw the filter element (see section 6.4.2.3).
Reinstall the dust trap cover to protect the air
intake system while cleaning the element.
– Carefully knock the end faces of the filter element
on a flat surface to remove the dry contaminant.
Never strike on a hard surface. Then blow dry air
up and down the pleats in the reverse direction of
normal flow; subsequently blow up and down the
pleats on both sides of the element. The air
pressure may not exceed 5 bar (73 psi) and a
reasonable distance must be maintained between
the hose nozzle and the pleats.
– If the contaminant is oily, soak the element for 10
minutes in luke-warm water in which a non-
foaming detergent is dissolved. Then, move the
element to and fro in the solution for 5 minutes.
– Rinse with soft water until the drain water is clear.
Let the element dry. Never use compressed air to
hasten drying.
– Inspect the element by placing a light inside it.
Spots or ruptures of the paper render the element
unfit for further use.
– Reassemble in reverse order of dismantling.
– Reset the air filter service indicator by pushing the
reset button (8).
7
Air filter contamination indicator
8
Reset button
9
Yellow indicator
Never run the compressor without
air filter element.
8
7
9
!
Содержание PTS 1600 Cud S3A/T3 APP
Страница 1: ...Instruction Manual for Portable Compressors English PTS 1600 Cud S3A T3 APP QSX15 ...
Страница 2: ......
Страница 89: ... 89 Circuit diagrams ...
Страница 97: ... 97 ...
Страница 103: ... 103 ...
Страница 115: ... 115 ...
Страница 123: ... 123 ...
Страница 126: ... 126 ...
Страница 127: ......
Страница 128: ...Printed in Belgium 12 2013 2954 7430 01 ...