SPC and Statistics
9836 3521 01
403
The SPC and TDA function will store and calculate data on
No. of subgroups to save
subgroups. It will
not display any values until at least
No. of subgroups to calculate
has been collected. However, from
that point it will use all subgroups stored in memory in the calculations.
The short
Term Trend function
is used to give a detailed view of the latest recorded samples. It uses a
buffer where the last (
Subgroup size
*
No. of subgroups to save)
samples are stored. Here are values
from both OK and NOK cycles collected.
When the Short Term Trend is to be displayed then average and the range or deviation values are
calculated for subgroups built from the data in the short Term trend buffer, starting with most resent value.
Which variables to collect are set up uniquely for each bolt/spindle and program.
7.2.2
Calculations for subgroups
Data in a subgroup is calculated as:
Average
X
X
n
i
n
i
;
..
1
Range
R
X
X
i
n
i
i
max(
)
min(
) ;
..
1
S
dard deviation
S
X
X
n
i
n
i
tan
(
)
;
..
2
1
1
S is approximated with
X
X
n
n
i
n
i
i
2
2
1
1
(
)
;
..
where n = size of subgroup
7.2.3
Calculations and checks
When specified number of subgroups to use for calculations has been collected, the SPC function will
start calculations to determine the statistical stability. This will be repeated every time a new subgroup is
ready.
Calculations are performed in following steps: (m = number of subgroups)
Calculation of Average of Average values:
X
X
m
i
m
i
;
..
1
Содержание PowerMACS 4000
Страница 1: ...User guide PowerMACS 4000 Atlas Copco Tools and Assembly Systems 9836 3521 01 2010 11 Edition 10 3 0...
Страница 2: ......
Страница 46: ...System Architecture 46 9836 3521 01...
Страница 127: ...Set Up and Maintenance 9836 3521 01 127 See chapter Station Set Up for a description of the parameters...
Страница 267: ...Tightening 9836 3521 01 267...
Страница 400: ...Tightening 400 9836 3521 01...
Страница 422: ...Peripheral Devices 422 9836 3521 01 When connected to a system the form will show show the signal values in realtime...
Страница 486: ...Peripheral Devices 486 9836 3521 01...
Страница 622: ...Peripheral Devices 622 9836 3521 01...
Страница 664: ...References 664 9836 3521 01...
Страница 668: ...9836 3521 01 2010 11 Edition 10 3 0 www atlascopco com...