Tightening
9836 3521 01
365
Time
Speed
Speed 1
Down ramp 1
Down ramp start point 1
Speed 2
Speed 3
Down ramp 2
Down ramp 3
Down ramp start point 2
Down ramp start point 3
6.5.6.2 Ramps & Other
– Other
The
Other
group holds parameters that do not belong to the earlier parts.
Specify in
Start delay for step
if you want a delay first in the step, before the main function starts.
If the checkbox
Wait for PLC at step end
is checked for at least bolt in the cycle the station will stop and
wait for the signal INTERMEDSTART from the PLC to continue running the cycle. This works like an
implicit synchronization point. Even if the step is lacking the synchronization point it will still report to the
station and wait for all other spindles.
In
Torque Spike Elimination
specify the angle for which all torque readings should be disregarded for
control.
Note!
The torque restriction (see chapter: Fail Safe Torque) is active also during the
Torque Spike
Elimination
phase.
Use the
Customer step name
combo to select the customer error code series that shall be used in this
step. See Set Customer step names and Set Customer error codes for more information about this
function.
By checking
Hold position when stopped
the bolt will be held in the position it has when zero speed is
detected. This option cannot be used together with the
Hold torque
stop condition.
Using the
Stop method
property you can set up how you want to stop the spindle when the target for the
step has been reached:
Inertia brake
. Choose this alternative if you want to stop as quickly as possible. This is the
recommended stop alternative for fastening.
Ramp down the current
. First lower the current to X % of the current value at target (
Initial
value
), and after that ramp down the current with the
Slope
[A/s]. Use this alternative to relax any
torsion built up in a controlled manner.
Содержание PowerMACS 4000
Страница 1: ...User guide PowerMACS 4000 Atlas Copco Tools and Assembly Systems 9836 3521 01 2010 11 Edition 10 3 0...
Страница 2: ......
Страница 46: ...System Architecture 46 9836 3521 01...
Страница 127: ...Set Up and Maintenance 9836 3521 01 127 See chapter Station Set Up for a description of the parameters...
Страница 267: ...Tightening 9836 3521 01 267...
Страница 400: ...Tightening 400 9836 3521 01...
Страница 422: ...Peripheral Devices 422 9836 3521 01 When connected to a system the form will show show the signal values in realtime...
Страница 486: ...Peripheral Devices 486 9836 3521 01...
Страница 622: ...Peripheral Devices 622 9836 3521 01...
Страница 664: ...References 664 9836 3521 01...
Страница 668: ...9836 3521 01 2010 11 Edition 10 3 0 www atlascopco com...