Instruction book
a
Increase pressure difference
b
Check valve leaks
b See
5a
7
High oil consumption on LE/LT compressors
a
Oil level too high
a
Do not overfill crankcase. Keep level in red circle of sight-glass
b
Piston ring(s) worn or broken
b
Have condition of piston rings checked
8
Unit does not start
a Electrical
failure
a
Have electrical system checked. Check fuses and line terminals for tightness
b
Overload relay cut out
b
Reset overload relay. If the relay cuts out again after starting, see point 9
c
Air pressure above pre-set starting pressure
c
Compressor will start when air pressure is lower than pre-set starting pressure of air pressure
switch
9
Overload relay cuts out
a
Overload relay incorrectly set
a
Check and adjust. Reset relay
b
Solenoid valve out of order
b See
1g
c
Unloader plunger jammed
c See
1f
d
Blow-off silencer choked
d See
2d
e
Ambient temperature too high
e
Improve ventilation of room
f
Motor stops and starts too frequently
f See
6
g
Overcurrent due to motor or compressor failure
g
Consult Atlas Copco
Footnote chapter 6
1)
If
provided.
2920 1585 00
- 63 -