2920 1207 05
20
User manual
indication and the start/stop indication. See Figs. 13.6
and 13.7.
5. Press the key <<Prog>> (program) to program the new
command or the key <<Canc>> (cancel) to quit without
reprogramming.
6. The regulator will ask if it is desired to change more
commands.
06:00 start
"Mon"
17:00 stop
07:00 start
Prog
Canc
F1
F2
F3
Fig. 13.4. Programming the day
Mon
start
Mon
"18" stop
Tue
start
Prog
Canc
F1
F2
F3
Fig. 13.5. Programming the hours
Mon
start
Mon
"00" stop
Tue
start
Prog
Canc
F1
F2
F3
Fig. 13.6. Programming the minutes
Mon
06:00
Mon
18:00 "stop"
Tue
07:00
Prog
Canc
F1
F2
F3
Fig. 13.7. Programming the start/stop mode
Important:
It is necessary to program the start/stop commands in successive
order timewise. Program the commands from Monday till
Sunday, e.g.:
Monday 07.30 start
Monday 18.00 stop
Tuesday 08.00 start
Tuesday 17.00 stop
etc.
The regulator does not accept a new compressor start/stop
command unless it is situated between the next and previous
start/stop command timewise. If not, the new command is not
accepted and the command line remains blinking. In this case,
either modify the command or use the key <<Canc>> (cancel)
to quit the modification operation.
Make sure that the timer function is activated (<<Timer
active>>). If not, the programmed start/stop commands will not
be executed.
13.2.5 To add a command
1. Press the key <<List>> and scroll through the commands
until the command after which a new command is to be
added appears, followed by a horizontal arrow.
2. Press the keys <<Mod>> (modify) and <<Add>>. 1) The
command which was indicated by the horizontal arrow will
be copied and the day indication of the copied command
will blink.
3. The way of modifying this command is similar to the
description in section 13.2.4.
4. The regulator will ask if it is desired to change more
commands.
13.2.6 To delete a command
1. Press the key <<List>> and scroll through the commands
until the command to be deleted appears, followed by a
horizontal arrow.
2. Press the keys <<Mod>> (modify) and <<Del>> (delete).
1) The bottom line of the screen shows following selections:
<<All>> to delete all commands
<<This>> to delete the command indicated by the horizontal
arrow
<<Canc>> (cancel) if the delete selection must not be carried
out
3. When selecting <<All>>, the regulator will ask <<Are you
sure to delete all commands?>> By pressing the key
<<Yes>> all commands are deleted.
4. The regulator will ask if it is desired to change more
commands. If so, press the keys <<Yes>> and<< Add>>.
Footnotes chapter 13
1) If the key <<Yes>> was pressed at the question <<Do you want
to change another command>>, the display will include the
options <<Add>> and <<Del>> (delete). In this case, one of
these keys can be pressed without using the key <<Mod>>
(modify) first.
Содержание GA5
Страница 2: ......
Страница 8: ...2920 1207 05 6 User manual Fig 4 1 General menu flow ...
Страница 9: ...2920 1207 05 7 User manual Fig 4 2 Menu flow for regulator of GA5 45 ...
Страница 10: ...2920 1207 05 8 User manual Fig 4 3 Menu flow for regulator of GA55 W 75 W 90C ...
Страница 28: ...2920 1207 05 26 User manual Notes Notes Notes Notes Notes ...
Страница 29: ...2920 1207 05 27 User manual Notes Notes Notes Notes Notes ...
Страница 30: ...2920 1207 05 28 Instruction book Notes Notes Notes Notes Notes ...