8
Problem solving
8.1
Problem solving
Warning
Before carrying out any maintenance, repair work or adjustment, stop the compressor,
press the emergency stop button and switch off the voltage. Close the air outlet valve and
open the manual condensate drain valves.
Open and lock the isolating switch.
The operator must apply all relevant
.
Control panel
Faults and remedies
A service message appears on the display
Stop the compressor and carry out the indicated service actions.
Reset the message:
•
Press the “Menu” key (3).
•
Press key (1) until “Service” is followed by an arrow pointing to the right. Activate the menu by pressing
key (2).
•
Press the “Reset” key (3); the timer is reset to 0.
A shut-down warning message appears on the display
The alarm LED will light up indicating that the temperature at the outlet of the compressor elements is too
high. The message disappears as soon as the cause of the problem is remedied.
Instruction book
108
2920 1475 06
Содержание GA110
Страница 1: ...GA 90 GA 110 GA 132 GA 160 GA 200 GA 250 GA 315 ...
Страница 2: ......
Страница 16: ...2 2 Air and oil system Flow diagrams Flow diagram of GA90 up to GA160 Instruction book 14 2920 1475 06 ...
Страница 17: ...Flow diagram of GA200 GA250 and GA315 60 Hz Instruction book 2920 1475 06 15 ...
Страница 21: ...2 4 Regulating system Flow diagrams Flow diagram of GA 90 up to GA 160 Instruction book 2920 1475 06 19 ...
Страница 30: ...Menu flow for GA 90 up to GA 315 simplified example Instruction book 28 2920 1475 06 ...
Страница 57: ...Dimension drawing of GA90 110 water cooled Instruction book 2920 1475 06 55 ...
Страница 58: ...Dimension drawing of GA132 160 and GR110 up to GR200 air cooled Instruction book 56 2920 1475 06 ...
Страница 59: ...Dimension drawing of GA132 160 and GR110 up to GR200 water cooled Instruction book 2920 1475 06 57 ...
Страница 60: ...Dimension drawing of GA200 250 and GA315 60 Hz air cooled Instruction book 58 2920 1475 06 ...
Страница 64: ...Compressor room example of GA 90 up to GA 160 water cooled Instruction book 62 2920 1475 06 ...
Страница 65: ...Compressor room example of GA 200 GA 250 and GA 315 60 Hz air cooled Instruction book 2920 1475 06 63 ...
Страница 76: ...Suspended solids Non soluble particles size 1 mm 10 ppm Instruction book 74 2920 1475 06 ...
Страница 98: ...Filler and drain plugs on GA 200 up to GA 500 compressors Instruction book 96 2920 1475 06 ...
Страница 102: ...Position of oil filter on GA 200 up to GA 500 Instruction book 100 2920 1475 06 ...
Страница 133: ...Instruction book 2920 1475 06 131 ...
Страница 134: ......
Страница 135: ......