Minimum
setting
Factory
setting
Maximum
setting
Integration time
sec
5
6
10
Minimum motor speed:
200 V and 230 V units
rpm
700
700
1000
500 V and 575 V units
rpm
600
600
1000
380 V, 400 V and 460 V units
rpm
600
600
1000
Maximum RPM reduction
%
75
100
100
Maximum motor speed:
Pressure setpoint
7.5 bar
Pressure setpoint
13 bar
200 V and 230 V units
rpm
2700
2060
500 V units
rpm
2850
2175
575 V units
rpm
2560
2100
380 V, 400 V and 460 V units
rpm
2560
2100
Parameters
Minimum
setting
Factory
setting
Maximum
setting
Minimum stop time:
GA 75 VSD
sec
5
5
30
GA 90 VSD
sec
5
5
30
Power recovery time
sec
10
10
3600
Restart delay
sec
0
0
1200
Communication time-out
sec
10
30
60
On air-cooled compressors also:
Fan motor starts per day
1
240
240
Protections
Minimum
setting
Factory
setting
Maximum
setting
Compressor element outlet temperature
(shut-down warning level)
˚C
50
110
119
Compressor element outlet temperature
(shut-down warning level)
˚F
122
230
246
Compressor element outlet temperature
(shut-down level)
˚C
111
120
120
Compressor element outlet temperature
(shut-down level)
˚F
232
248
248