Problem solving
Warning
•
If the compressor is stopped because the supply voltage is interrupted, please
be aware that it will restart automatically when the power is restored!
See also
section
.
•
Before carrying out any maintenance, repair work or adjustment, stop the compressor
(see section
). Wait until the compressor has stopped (approx. 30 seconds),
press the emergency stop button and switch off the voltage. Close the air outlet valve,
open the manual drain valve. Depressurise the compressor by opening the oil filler
plug (FC) one turn.
For location of components, see sections
,
.
Open and lock the isolating switch.
The air outlet valve can be locked during maintenance or repair as follows:
•
Close the valve.
•
Remove the screw fixing the handle with the wrench delivered with the compressor.
•
Lift the handle and turn it until the slot of the handle fits over the blocking edge on the
valve body.
•
Fit the screw.
The operator must apply all relevant
Faults and remedies, compressor
On compressors equipped with an Elektronikon® Graphic controller, if the alarm LED is lit or flashes, consult
sections
Condition
Fault
Remedy
Compressor starts running, but
does not load after a delay time
Solenoid valve out of order
Replace valve
Inlet valve stuck in closed position
Have valve checked
Leak in control air tubes
Replace leaking tubes
Minimum pressure valve leaking
(when net is depressurised)
Have valve checked
Compressor does not unload,
safety valve blows
Solenoid valve out of order
Replace valve
Inlet valve does not close
Have valve checked
Condensate is not discharged from
condensate separator during
loading
Discharge tube clogged
Check and correct as necessary
Float valve malfunctioning
(condensate drain, units without
dryer)
Remove float valve assembly,
clean and check
Compressor air output or pressure
below normal
Air consumption exceeds air delivery
of compressor
Check equipment connected
Choked air filter element
Replace filter element
Solenoid valve malfunctioning
Replace valve
Leak in control air tubes
Replace leaking tubes
Inlet valve does not fully open
Have valve checked
Instruction book
2920 7104 10
85
Содержание GA 11 VSD MED
Страница 2: ......
Страница 41: ...3 11 Service menu Control panel 1 Scroll keys 2 Enter key 3 Escape key Instruction book 2920 7104 10 39 ...
Страница 63: ...4 Installation 4 1 Dimension drawings Instruction book 2920 7104 10 61 ...
Страница 64: ...4 2 Installation proposal Instruction book 62 2920 7104 10 ...
Страница 102: ......
Страница 103: ......