5
Operating instructions
5.1
Initial start-up
Safety
The operator must apply all relevant
Procedure
For the location of the air outlet valve and the drain connections, see sections
and
.
Position of oil sight glass
-
Consult the sections
.
-
Check that the electrical connections correspond to the applicable codes and that all wires are clamped
tight to their terminals.
The installation must be earthed and protected against short circuits by fuses of the inert type in all
phases. An isolating switch must be installed near the compressor.
-
Check transformer (T1) for correct connection.
-
Fit air outlet valve (AV); see section
for the location of the valve.
Close the valve.
Connect the air net to the valve.
Instruction book
66
2920 7104 10