7
Adjustments and servicing procedures
7.1
Drive motor
General
Keep the outside of the electric motor clean for efficient cooling. If necessary, remove dust with a brush and/
or compressed air jet.
Bearing maintenance
The motor bearings do not need to be regreased during their normal service life.
7.2
Air filter
Location of air filter
Air filter
Recommendations
1. Never remove the element while the compressor is running.
2. For minimum downtime, replace the dirty element by a new one.
3. Discard the element when damaged.
Procedure
1. Stop the compressor. Switch off the voltage.
2. Remove the cover of air filter (AF) by turning it anti-clockwise. Remove the filter element. If necessary,
clean the cover.
3. Fit the new element and the cover.
4. Reset the air filter service warning.
For compressors equipped with an Elektronikon® Graphic regulator, see section
.
Instruction book
78
2920 7104 10
Содержание GA 11 VSD MED
Страница 2: ......
Страница 41: ...3 11 Service menu Control panel 1 Scroll keys 2 Enter key 3 Escape key Instruction book 2920 7104 10 39 ...
Страница 63: ...4 Installation 4 1 Dimension drawings Instruction book 2920 7104 10 61 ...
Страница 64: ...4 2 Installation proposal Instruction book 62 2920 7104 10 ...
Страница 102: ......
Страница 103: ......