1.
Refer to
on page 22 for cable sizes and type to determine the
most appropriate cable for the dry pumping system.
2.
Screw the cable gland onto the terminal.
3.
Pass the cable through the cable gland. Cables must be with M5 lug to ensure
correct clamping in the main terminal.
4.
Fit the earth (ground) wire to the protective earth connection.
If further information is required about connecting the electrical supply, contact us
for advice.
6.9.2.
EMC filter
WARNING: PROTECTIVE EARTH CONNECTION
Risk of injury or damage to the equipment. Ground the neutral point on the
power supply to comply with the EMC directive before turning on the EMC filter.
CAUTION: DRIVE DAMAGE
Risk of drive damage. When using a drive with a non-grounding network, high
resistance grounding or asymmetric grounding network, place the screw for the
EMC filter switch in the OFF position and disable the built-in EMC filter. Failure
to comply could cause damage to the drive.
The drive has a built-in EMC filter. The EMC filter switch is in ON position by
default. Move the screw position to switch ON (enable) and OFF (disable).
Figure 20
EMC filter switch location
1.
Switch ON
2.
Switch OFF
1.
Switch ON
2.
Switch OFF
Installation
07/2021 - ©Atlas Copco
Page 94
1950840208_A