![Atlas Copco 8423013301 Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/atlas-copco/8423013301/8423013301_product-instructions_3001894014.webp)
Operation
EN
LSV39 SA12-125
14
© Atlas Copco Industrial Technique AB - 9839 0621 01
WARNING Risk of injury.
►
Make sure to wear the appropriate personal protection equipment before operating the tool.
►
Always wear protective gloves when replacing accessories or when making repairs.
►
Make sure that the working area is kept free from other people so that no one can get injured.
►
Make sure that the workpiece is safely attached before working with the workpiece.
►
Drain the hose of air pressure before connecting the tool to the air supply.
►
Never remove or fix the throttle lever or security mechanism with tape or similar.
►
Make sure that the selected combination of abrasive equipment and attachments parts corre-
spond to national regulations.
►
Make sure that the abrasive equipment is not cracked or damaged.
►
Make sure that the maximum speed of the abrasive equipment is greater than or equal to the
speed marked on the tool.
►
Make sure that the speed of the tool is not more than the speed marked on the tool.
►
When working with the tool, always hold the tool with two hands and in such a way that both
hands are kept away from the machining point.
►
Make sure you always have a secure footing when working with the tool.
►
Always operate the tool in the recommended working direction.
►
When the tool is running or connected to the air line, never touch any rotating parts.
►
Never use the tool above head height.
►
Stop using the tool if abnormally loud noises and vibrations occur during use.
Instructions
1.
Connect the tool to the air supply (if not already connected).
2.
Point the air exhaust away from the operator.
3.
Push the security mechanism to release the throttle lever.
4.
Push down the throttle lever to start the grinder.
Replace the throttle lever if it is not working properly.
WARNING Risk of Damage and Injury
Rotating parts may cause damage and injury
►
Make sure that the tool is switched off and has stopped rotating before putting it down.