11
Temperature setting knob with Hors Gel
position and ability to restrict the range.
Time adjustment knob TURBO 1/4h, 1/2h,
1h, 2h.
Power On indicator
TURBO indicator
TURBO control
Heating ON/OFF switch
Heating indicator
U
SING THE DEVICE
1) Description of the control panel
5) Programming
With a pilot wire:
The device can be controlled remotely if its pilot wire is connected to an device fitted with a pro-
grammer, to a central programming unit or to an energy control system.
With a separate programmer:
The device can also be programmed independently by inserting a programmer in the housing at the
rear of the control box. This programmer will create the ECO and COMFORT modes just as you
have defined them for your device.
Chart indicating the orders the device can receive over its pilot wire
(
to be measured between the pilot wire and the neutral
).
Orders received Current absent
Full alternance
230V
Negative half-
alternance
-115V
Positive half-alter-
nance +115V
Ref/neutral
oscilloscope
Mode achieved
CONFORT
ECO
STANDBY
STOP LOAD
SHEDDING
Heating
temperature
CONFORT
setting
3°C to 4°C
below
CONFORT
setting
Standby
temperature,
about 7°C
Stopping the hea-
ting immediately.
Can also be used
for load shedding.
2) Setting the CONFORT temperature
It is the temperature desired when the room is occupied.
a) Set the switch to
to the ON position, the
indicator lights.
b) Align the toothed screw
with the marking : the indicator light
illuminates if the tempe-
rature is less than desired.
Wait a few hours for the temperature to stabilise.
If the temperature setting does not suit you, adjust it using the adjusting screw
. Proceed step-
by-step using the notches (
one notch at a time
).
The thermostat’s cycle takes several minutes. It is possible that the heating indicator may not react
instantaneously, but instead only on the next thermostat cycle.