Atlantic O'Pro 272014 Скачать руководство пользователя страница 10

10

requirement of AS 3500.4 & NZBC G12 that both a Stop Valve and a 
Non Return Valve are installed upstream of the Product.

 
 No parts (stop valve, pressure reducer, etc.) must be placed between the 

pressure limiting valve and the cold water inlet of the water heater, 
apart from a copper pipe.

 

Note: since limited water discharge from pressure limiting valve is normal 

in the heating operation, the discharge pipe needs be connected to 
external drain.

Commissioning 

Never switch the water heater on without it being filled with water.
Before switching on, open the hot water taps, bleed the pipes until no air 

is present and fill the appliance.

Check that the pipes and the door seal under the cover are not leaking. 

If there are any leaks tighten gently. Check that the water safety 
devices are working and fill the appliance. Switch on the appliance. 
After 5 to 20 minutes according to the capacity of the appliance, 
water should start dripping from the drain outlet. This is normal 
and results from the expansion of the water. 

Check that joints and seals are watertight. In the course of heating up, 

shielded water heaters may make a boiling noise; this is normal 
and does not indicate any fault with the appliance.

To avoid the development of bacteria (legionella…) ensure that a 

temperature of 60°C is reached every day. The thermostat is set at 
the factory at 65°C. Maximum is 71°C.

User Maintenance

Operates once a month the PTR valve to prevent scaling and verify that it 

is not blocked. If this is not done, damage may be caused and the 
guarantee invalidated.

 

Содержание O'Pro 272014

Страница 1: ...14 150 Litre MODEL 282029 200 Litre MODEL 282035 250 Litre MODEL 292039 300 Litre PREMIUM SERIES MAINS PRESSURE ELECTRIC STORAGE WATER HEATERS DOCUMENTATION FOR INSTALLATION AND OPERATION New Zealand...

Страница 2: ...to provide abundant hot water efficiently and trouble free for many years To keep track of your warranty please register this purchase at our web site www atlantic nz If additional information is requ...

Страница 3: ...s protected from frost If the appliance is damaged because the PTR valve safety device has been blocked it is not covered by warranty If the appliance is to be fitted in a room or location where the a...

Страница 4: ...d water PTR valve 850 kPa Drain Lines Untempered Hot water Kitchen Laundry Tempered water 50 C Bathrooms 1 2 3 4 1 Non return and isolating valve 2 Line Strainer 3 Pressure Limiting valve 350 500 kPa...

Страница 5: ...the water heater In addition to the Pressure Limiting Valve it is a requirement of AS 3500 4 NZBC G12 that both a Stop Valve and a Non Return Valve are installed upstream of the Product No parts stop...

Страница 6: ...lve and drain line must not be sealed or blocked Electric Connection All electrical work must be carried out by a registered electrician and in accordance with AS NZ 3000 The Atlantic ESWH must be fil...

Страница 7: ...out continues to trip replace the thermostat Never by pass the safety device or the thermostat Connect the power supply only via the terminal The thermal cut out fitted to the auxiliary electric heat...

Страница 8: ...are Following reconnection at the cold water inlet the cold water stop valve is now opened fully and the water heater may be filled with cold water and flushed through to ensure the cylinder contains...

Страница 9: ...be facilitated by correct orientation of the cover positions when installing There are no operational clearance limitations to surrounding structure PTR valve removal requires approximately 150 mm fo...

Страница 10: ...under the cover are not leaking If there are any leaks tighten gently Check that the water safety devices are working and fill the appliance Switch on the appliance After 5 to 20 minutes according to...

Страница 11: ...y of cold water open the hot water faucets and manipulate the safety valve before performing these operations Refit the heating element and tighten the screws gently opposite screws in sequence check...

Страница 12: ...rvice agents report or receipt invoice detailing maintenance history would be required with any claims under this warranty Should this ESWH be installed in a regional location where regular flushing i...

Страница 13: ...safety unit PTR valve No maintenance of safety unit PTR valve leading to excess pressure Modification of equipment without notifying the manufacturer Use of spare parts not recommended by manufacture...

Страница 14: ...s 10 If the system is either sold and or repaired or altered by any third party without the consent of Atlantic Australasia Pty Ltd 11 Does not cover fair wear tear particularly from adverse condi tio...

Страница 15: ...UST be from a supplied reticulated source or from rainwater to ensure Warranty compliance Warranty Water Heater Tank Domestic 7 years Water Heater Tank Commercial 3 years Warranty conditions apply Tan...

Страница 16: ...FOR INFORMATION REPAIRS AND SERVICE NEW ZEALAND 0800 422 000 For Warranty Registration Register Online www atlantic nz email info atlantic nz...

Отзывы: