Atlantic LST 500W Скачать руководство пользователя страница 4

4

Set time

Press and hold for 5 secons

Temperature set

When display shows room 
temperature press to adjust

Mode selection

Boost, manual setback and 
program

Set programme

Press and hold for 5 
seconds

1. Basic Operation

When the appliance is connected to the mains supply and the 
wall socket is switched ‘ON’, the LED indicator on the moulding 
will light up green, showing that the power is available to 
the unit. Before you can use the LST, it has to be activated 
by pressing any control button. The LCD backlight will turn 
on. To operate any control button, press within 2 seconds of 
activation.

2. Time and day setting

•  Press and hold the TIME button for 5 seconds. Minutes are 

flashing - use TEMP and MODE buttons to set minutes.

•  Press TIME button Hours are flashing - use TEMP and MODE 

buttons to set hours.

•  Press TIME button Day is flashing - use TEMP and MODE 

buttons to set Day.

Once you are happy with the settings, press ‘Time’ to return to 
main screen.

3. Selecting operating mode

LST has 4 operating modes: BOOST, MANUAL, SET BACK, 
PROGRAM. Each mode can be selected by pressing the MODE 
button to cycle through the options. The cycle sequence will 
always start with BOOST mode followed by MANUAL, SET BACK 
and PROGRAM.

4. BOOST - 15 minutes

The boost feature increases the room temperature for 15 
minutes.

1. Use TEMP and MODE to set the temperature.

To amend the set temperature when in Boost mode, simply 
activate the display by pressing any button. Press TEMP, then 
use TEMP and MODE to change the temperature. Once the 
temperature is set, you can leave the display to return to the 
main screen and the settings will be saved. After 15 minutes, 
the LST will return to previous operating mode.

5. MAN - Manual Mode

In manual mode, the heater maintains the set temperature.

1. Use TEMP and MODE to set the temperature.

To amend the set temperature when in Manual mode, simply 
activate the display by pressing any button. Press TEMP, then 
use TEMP and MODE to change the temperature. Once the 
temperature is set, leave the display to return to the main 
screen and the settings will be saved.

6. SETB - Reduction in programmed 
temperature

In the setback (ECONOMY) mode, LST lowers all temperatures 
in the 7-day programme by a set value. You can set how much 
to lower the programme temperatures in SETB mode by simply 
activating the display, pressing TEMP and using TEMP and 
MODE to set the new value.

The display will first show the temperature difference and after 
2 seconds the new set temperature.

7. PROG - Automatic time mode

In this mode, the LST will follow the week’s time / temperature 
programme. You can temporarily override the temperature 
in PROG mode by simply activating the display and using the 
TEMP and MODE buttons to set the new temperature. The 
new set temperature will be then maintained until the next 
program step.

Содержание LST 500W

Страница 1: ...s provided and has not been connected to an unsuitable electricity supply or subject to misuse neglect damage or modified or repaired by any person not authorised by the Company This guarantee is offered to you as an extra benefit and does not affect your legal rights The correct electricity supply voltageisshownontheratinglabelattachedtotheappliance Reasonablecarehasbeentakentoensurethatthisguide...

Страница 2: ...e pole switch having 3mm gap on each pole A switched Fused Connection unit to BS 1363 Part 4 is a recommended mains supply connection accessory to ensure compliance with safety requirements applicable to fixed wiring installation Note When switched on for the first time the appliance may emit a slight smell This is purely the evaporation of a fluid used in the manufacturing process WARNING This ap...

Страница 3: ...3 ...

Страница 4: ... TEMP and MODE to set the temperature To amend the set temperature when in Boost mode simply activate the display by pressing any button Press TEMP then use TEMP and MODE to change the temperature Once the temperature is set you can leave the display to return to the main screen and the settings will be saved After 15 minutes the LST will return to previous operating mode 5 MAN Manual Mode In manu...

Страница 5: ...ture press PROG to set temperature To add another programme repeat steps 2 10 The LST has a 7 day timerwith up to 6 programming steps available for each day In the programming you can set a start time and a temperature for each programme Each programme has to be used 9 Advance mode Press PROG from PROG mode to bring forward the next programme To clear advance mode press PROG 10 Heat symbol on the ...

Страница 6: ...o C in less than 30 seconds is detected the heaterwill switch itself back on this temperature can be changed in menu 9 and time in menu 8 14 Setup Menu 1 Press and hold TEMP and MODE together for 5 seconds 2 The display will enter the setup menu 3 Use TEMP and MODE to change a value 4 Use TIME to scroll between the settings 01 Temperature calibration The temperature reading has been factory calibr...

Страница 7: ... Operated Cut out Check that the fuse in the spur unit has not blown This can be done by replacing the fuse with another suitable fuse Should none of the above remedies work then telephone the helpline number shown in these instructions UK ONLY Do not attempt to repair the heater CUSTOMER HELPLINE Should you need any advice on the use of your new Atlantic Heat product please contact our Helpline A...

Отзывы: