• DHW boost
(without room thermostat).
A DHW boost function is available (on the user interface:
, parameter
95
- see
page 13
). This DHW
boost enables the DHW to be heated to the comfort
temperature at any time during the day. The boost
function is cancelled automatically when the demand
for hot water has been met.
• DHW boost
(with room thermostat).
See the instructions for the thermostat.
▼
Changing the DHW timer programme
The default DHW timer programme is set for the whole week (Monday to Sunday: 10):
from 12 a.m. to 5 a.m. (1st DHW heating phase) and from 2:30 p.m. to 5 p.m. (2nd DHW heating phase).
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
start of
comfort heating
Comfort T°
Comfort T°
Reduced T°
Reduced T°
1
st
phase
2
nd
phase
end of comfort
heating
end
start
For your comfort you can set up to 2 DHW heating phases and apply these over di
ff
erent time periods (week, day etc.).
- Example :
Monday to Sunday [parameter 25 set to 10] (see table)
2 phases [12 a.m.-7 a.m. / 1:30 p.m.-5 p.m. and 5 p.m.-10:30 p.m.] (set parameters 26 to
29, see table),
Press the
button to enter the "user" menu: the
icon is displayed.
Selecting the line No.
Settings
N°25
Select the day(s):
10
: Mon-Sun,
8
: Mon-Fri,
9
: Sat-Sun,
1
: Monday,
2
: Tuesday,
3
: Wednesday,
4
: Thursday,
5
: Friday,
6
: Saturday,
7
: Sunday
E.g.: 10 (Monday to Sunday)
N°26
start of comfort heating:
Start-up time
for the 1
st
heating phase
.
E.g.: 00:00
N°27
end of comfort heating:
Shutdown time
for the 1
st
heating phase
.
E.g.: 07:00
N°28
start of comfort heating:
Start-up time
for the 2
nd
heating phase
.
E.g.: 13:30
N°29
end of comfort heating:
Shutdown time
for the 2
nd
heating phase
.
E.g.: 17:00
- Continue programming for another day (line 25).
ou
- Press
to return to the basic display.
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
start
Comfort T°
Reduced T°
Reduced T°
Comfort T°
1
st
phase
2
nd
phase
end
end
start