Atlantic Loria 6000 R32 Скачать руководство пользователя страница 1

For professionals and users

To be kept by the user for future reference

EN

USE

Loria 6000 R32

Loria Duo 6000 R32

Air/water heat pump split system

U0710300_2259_EN_1
20/09/2021

Содержание Loria 6000 R32

Страница 1: ...For professionals and users To be kept by the user for future reference EN USE Loria 6000 R32 Loria Duo 6000 R32 Air water heat pump split system U0710300_2259_EN_1 20 09 2021 ...

Страница 2: ...n of Hot water 10 Absence 12 Standby 12 Regulation parameters 13 Overview 13 List of End User parameters 13 Displaying information 14 Maintenance 16 Regular checks 16 Outdoor unit check 16 Domestic hot water tank 16 Error messages 16 Warning Risk of serious injury to the person and or risk of damage to the machine Observe the warning Important information that must always be kept in mind Tips and ...

Страница 3: ...thin and can cause cuts Nothing should obstruct the air circulation through the evaporator and out from the fan The outdoor unit must only be installed outside If a shelter is required it must have broad openings on all 4 sides and respect the installation clearances see your installation engineer Do not climb on the outdoor unit Caution copper pipes that carry refrigerating fluid may be hot and c...

Страница 4: ... the ambient temperature is taken into account Radiators In order to ensure operation of the control system the room containing the thermostat must not also contain a thermostatic valve If this is the case it must be opened as far as possible Underfloor heating system A new underfloor heating system must initially be heated slowly to avoid any problems involving cracking Check with your installer ...

Страница 5: ...s The outdoor sensor Optional controller The cooling kit The DHW kit The 2 area kit The outdoor unit The hydraulic unit The domestic hot water tank with electrical back up The heating circuit floor heating cooling system Dynamic radiators or fan coil heaters Radiators depending on configuration option Loria 6000 R32 Loria Duo 6000 R32 USE 2259 EN ...

Страница 6: ...ayed Cancel a modification being made 5 Configuration Access the user level press and release the icon appears 6 OK Confirm Configuration Setpoint for the pre selected mode 7 Display Display see Display Description View the settings User interface 1 7 3 6 4 2 5 Some settings or menus might not be displayed They are dependent on the installation s confi guration and installed options Setting parame...

Страница 7: ...mme set on the room thermostat Display Description Icons Definitions Constant mode with reduced temperature setpoint or Constant mode for heating or cooling with comfort temperature setpoint Absence mode The use concerned is in Off mode area 1 2 DHW Read information Access the Installer settings 1 Frost protection provided that the electric power supply to the HP is not switched off Some settings or...

Страница 8: ...me The hour display flashes 3 Press the or button to set the hour 4 Press to confirm The minutes display flashes 5 Press the or button to set the minutes 6 Press to confirm The settings are saved 7 Press the or button to change other settings or the 8 Press to return to the basic display Time setting 1 2 4 3 6 5 7 8 Loria 6000 R32 Loria Duo 6000 R32 USE 2259 EN ...

Страница 9: ...rmostat Change the temperature setpoint using the following buttons and With room thermostat See the instructions for the thermostat Press the button to select the heating use Confirm with the key Loria 6000 R32 Loria Duo 6000 R32 USE 2259 EN ...

Страница 10: ...e time programme Constant comfort mode Constant reduced mode Off mode for DHW Confirm with the key When browsing the temperature setpoints can be modified at any time using the or buttons Press to confirm Before exiting check that you have confirmed the desired mode In the event of extreme outdoor temperatures the electrical back up system of the DHW tank must be left in operation to guarantee a DH...

Страница 11: ...y these over different time periods week day etc Example Monday to Sunday parameter 25 set to 10 see table 2 phases 12 a m 7 a m 1 30 p m 5 p m and 5 p m 10 30 p m set parameters 26 to 29 see table Press the button to enter the user menu the icon is displayed Selecting the line No Settings N 25 Select the day s 10 Mon Sun 8 Mon Fri 9 Sat Sun 1 Monday 2 Tuesday 3 Wednesday 4 Thursday 5 Friday 6 Satu...

Страница 12: ...off the general power supply Without room thermostat For heating Press the button to select the heating use Press the button to select the Off mode For hot water Press the button to select the Hot water use Press the button to select the Off mode Using standby mode enables you to Keep all the safety mechanisms related to the appliance Maintain frost protection for the appliance But does not provide f...

Страница 13: ... the selected day end of comfort 00 15 24 00 17 00 Heat pump 72 Switch from summer winter according to the outdoor temperature 15 30 C 18 C When the average of the outdoor temperatures reaches 18 C the regulator switches off the heating as an economy measure 73 Legionella function 1 0 off 1 on 0 74 Correction of outdoor temperature sensor 1 5 5 C 82 Activation of summer time 0 no 1 yes 1 95 DHW boos...

Страница 14: ...his year MWh 33 Heat Energy consumed last year MWh 40 Cool Energy consumed this month kWh 41 Cool Energy consumed last month kWh 42 Cool Energy consumed this year MWh 43 Cool Energy consumed last year MWh 50 DHW Energy consumed this month kWh 51 DHW Energy consumed last month kWh 52 DHW Energy consumed this year MWh 53 DHW Energy consumed last year MWh Operating counter 60 Number of hours HP ON h ...

Страница 15: ...e 2 Reduced heating mode 3 Comfort cooling mode 4 Reduced cooling mode 5 Absence mode 6 Controlled by the room thermostat 7 Frost protection activated 8 Floor drying mode 9 Rate input activated No Value DHW status 16 0 Pending 1 Comfort mode charge activated 2 Reduced mode charge activated 3 Legionella charge 4 Frost protection activated 5 Forced operation boost Loria 6000 R32 Loria Duo 6000 R32 U...

Страница 16: ...it check Remove any dust from the exchanger making sure you do not damage the blades Check that there is nothing hindering the air flow Domestic hot water tank Maintenance on the tank must be carried out regularly frequency may vary according to water hardness Consult your heating engineer Error messages The faults or breakdowns of the hydraulic unit are reported on the display unit of the user in...

Страница 17: ...sed service The appliances must not under any circumstances be thrown out with household waste bulky waste or at a tip At the end of its service life please contact your installer or local representative to proceed with its dismantling and recycling Loria 6000 R32 Loria Duo 6000 R32 USE 2259 EN ...

Страница 18: ... ...

Страница 19: ... ...

Страница 20: ...formed by a qualified installer in compliance with the local and national legislation in force This unit must be recycled by a specialised service and in no case may it be thrown away with household waste rubble or in a landfill Please contact your installer or local representative for more information Depending on the national regulations of each member state Date de la mise en service Coordonnée...

Отзывы: