The Colorfalls must be accessible for  
service and maintenance. The LED light  
bar is accessed from the side of the  
Colorfalls body (Figure 2). Installing the  
Colorfalls so that the entire body is  
removable is highly recommended. Do  
not glue the cap stones above the  
Colorfalls or permanently mortar the  
Colorfalls in place.

3

Plumbing the Colorfalls

T

he Colorfalls has a 1½" female pipe thread inlet located at the center-back of each unit. 

Connect the plumbing using a 1½" male threaded fitting (not included) of your choice.  
Apply silicone to the threads of the male fitting. Screw the fitting into the Colorfalls inlet 
until tight. 

Hand-tighten only. 

Tightening too hard may crack the back of the unit.

Connect the plumbing line from the pump to the Colorfalls, using a minimum 1½" diameter 
tubing is recommended. Narrower tubing will cause inadequate flow and a broken sheer. 
PVC pipe is recommened because corrugated tubing with insert fittings restrict flow. 
Installing a ball valve (not included) on the feed line between the pump and the Colorfalls is 
recommended for added control of water flow. 

Figure 2

Operation

Connect the light bar to the transformer using the two pronged quick-connect plug. Plug 
the 12 volt AC transformer into a standard 120 volt outlet. Connect the tubing to the  
properly sized pump (not included) and turn the pump on. 

Warranty

Colorfalls and all its components carry a one-year limited warranty. This limited warranty is 
extended solely to the original purchaser commencing from the date of the original  
purchase receipt and is void if any of the following apply:

•  The Colorfalls has been misused or abused.

•  The Colorfalls has been disassembled or modified other than as described in this manual.

This warranty excludes labor and costs of labor for removal or installation of  any product

Maintenance

Atlantic’s Colorfalls is a one-piece, closed unit. If debris enters the body of the Colorfalls, it is 
extremely difficult to remove. For this reason, take great care to ensure that any debris in the 
water is filtered out before reaching the pump. Clean blockages in the lip with an Atlantic 
CFBRUSH Colorfalls Brush. 

For winterizing, disconnect the plumbing in the back and suck the water out with a shop 
vac or blow it out with an air compressor. The best option is to fully remove  
it from the wall and store indoors.

Содержание 73833

Страница 1: ...B 73833 CF12SW 73844 CF12W 73885 CF24B 73886 CF24SW 73887 CF24W 73888 CF36B 73889 CF36SW 73890 CF36W 73891 Product Manual Manuel du Produit Manual del Producto 1 330 274 8317 www ATLANTICWATERGARDENS com FS ...

Страница 2: ...electrical shock product failure or other problems Follow all aspects of electrical codes when installing the Colorfalls To reduce the risk of electrical shock connect only to a 110 volt receptacle protected by a ground fault circuit interrupter GFCI Colorfalls are designed for use in Pond free and fountain applications Colorfalls are not intended for use in water gardens or any pond with plant or...

Страница 3: ...d control of water flow Figure 2 Operation Connect the light bar to the transformer using the two pronged quick connect plug Plug the 12 volt AC transformer into a standard 120 volt outlet Connect the tubing to the properly sized pump not included and turn the pump on Warranty Colorfalls and all its components carry a one year limited warranty This limited warranty is extended solely to the origin...

Страница 4: ...Clear debris from pump intake Check pump manual for cleaning Obstruction in plumbing line Clear any debris from plumbing Waterfall sheer is splitting Debris in Colorfalls spillway Refer to Maintenance Not enough water flow Double check pump flow See diminished water flow Troubleshooting Guide Always turn off power before inspecting the Colorfalls Failure to observe this precaution can result in a ...

Страница 5: ...are avec des plantes et de la vie aquatique Elles doivent rester accessibles pour les interventions de service et d entretien Les installer de façon à ce que leur corps entier soit amovible est fortement recommandé Ne collez pas les pierres de couverture par dessus la Colorfalls et ne la scellez pas en place de façon permanente avec du mortier La chute peut supporter 40 lbs par pied linéaire ou 18...

Страница 6: ... arrière du corps Raccordez la conduite de plomberie venant de la pompe sur la Colorfalls l utilisation de tube d au moins 1 3 8cm de diamètre est recommandée Un tube plus étroit amènera un flux inadéquat et une cascade brisée Du tuyau en PVC est recommandé parce que du tuyau annelé avec raccords d insertion réduit le flux L installation d une vanne à boisseau non incluse sur la conduite d aliment...

Страница 7: ...ns Si vous n y décelez pas la solution au problème contactez votre revendeur Problème Cause possible Solution possible La rampe lumineuse ne s allume pas Pas de secteur sur la prise Confirmez la présence de secteur à la prise Pas d alimentation depuis le transformateur Confirmez la sortie de tension du transformateur Pas d alimentation à la barre lumineuse Contrôlez si le cordon est endommagé De l...

Страница 8: ...destinadas a su empleo en jardines acuáticos ni en ningún estanque con vida vegetal o acuática Las Colorfalls deben ser accesibles para el servicio y el mantenimiento Se recomienda especialmente instalar las Colorfalls de manera que el cuerpo completo sea desmontable No adhiera las piedras cimeras que están sobre las Colorfalls ni asiente con mortero las Colorfalls para instalarlas de manera perma...

Страница 9: ...io de una conexión roscada macho de 1 3 8cm a elección no incluida Aplique silicona a las roscas de la conexión macho Enrosque la conexión en la entrada de la Colorfalls hasta ajustarla Apriete sólo con la fuerza de la mano Si se aprieta demasiado se puede romper el dorso de la unidad Mantenimiento La Colorfalls de Atlantic es una unidad cerrada de una sola pieza Si ingresan desperdicios en el cue...

Страница 10: ... de plomería de la parte posterior y aspire el agua con una aspiradora de taller o sóplela con un compresor de aire La mejor opción es quitarla totalmente de la pared y almacenarla en interiores Problema Causa posible Solución posible La barra de luces no se enciende No llega alimentación eléctrica al tomacorriente Confirme que llegue alimentación eléctrica al tomacorriente No hay alimentación elé...

Страница 11: ...11 ...

Страница 12: ...1 330 274 8317 www ATLANTICWATERGARDENS com ...

Отзывы: