This air conditioner is equipped with two filter sets:
1. A multi layer filter in the upper air inlet, to clean the circulated room air, which 

includes:

a. A screen filter, to remove dust particles.
b. An active carbon filter, to remove odours.
c. 3M™ High Air Flow filter; to remove unhealthy particles from the air such as 

pollen, bacteria, animaldander and dust. Selected models have the 3M™ High 
Air Flow fillter as standard. However, if you require to add this to your model, 
or wish to purchase a replacement, call Atlantic for details.

2. A screen filter in the lower air inlet, to remove dust particles.

noTE! 

The active carbon filter and the 3M™ High Air Flow filter are delivered in a 

plastic packaging. Don’t forget to install these filters.

cleaning the air filters

a. The screen filters in the upper and lower air inlet should be cleaned regularly by rinsing 

them under running water.

b. The positive/negative electrostatically charged 3M™ High Air Flow filter is 

recommended to be changed every 3 months. Unusual dirt, construction work, pets, 
the presence of smoke and running the air conditioning unit continuously can shorten 
the life time of the 3M™ High Air Flow filter.

c. The active carbon filter can be cleaned with a vacuum cleaner when dusty but has to be 

changed at the same time as the 3M™ High Air Flow filter.

Filter installation

• Slide out the filter holder from the unit. 

• Separate the filter fixer from the filter holder (see fig. 1). 

• Remove the active carbon filter (black) and the 3M™ High Air Flow filter (white) 

from its plastic bag. 

• Insert the active carbon filter into the filter holder (see fig. 2). 

• Insert the 3M™ High Air Flow filter into the filter holder (see fig. 3). 

• Fix the filter by reassembling the fixer into the filter holder (see fig. 4). 

Air FiLTErS

1

2

3

4

Содержание 12KEHPW-410

Страница 1: ...s c o l b o n o m B M L P PLMB ENGLISH INSTRUCTION MANUAL 9KEHPW 410 12KEHPW 410 15KEHPW 410 ...

Страница 2: ...h care This appliance is not intended for use by young children or infirm persons unless they have been adequately supervised by a responsible person to ensure that they can use the appliance properly Young children should be supervised to ensure that they do not play with the appliance Do not clean the air conditioner by spraying it or immersing it in water Do not insert any object into openings ...

Страница 3: ... lift or move by pushing the air conditioner at the rear but always at the front side WARNING Do not use your air conditioner under the following conditions Close to a naked flame Inside unit exposed to the weather outdoors Near water If the power cable wires are frayed or cut When small children may be left unattended If an extension lead may become overloaded Where the power cable may be damaged...

Страница 4: ... 3 Carrying handle 4 Caster wheels 5 Grill housing 6 Upper air inlet 7 Exhaust air outlet 8 Lower air inlet 9 Cable storage 10 Drainage point with water stopper Controls ON OFF UP DOWN MODE TIMER Display COOLING FAN HEAT HOURS MINUTES TEMPERATURE 1 2 3 4 ...

Страница 5: ...ic slide bar Exhaust hose Water container Remote control with LCD 3M High Air Flow filter Optional Spiral Water Pipe with Connector CONTROL PANEL Controls ON OFF UP DOWN MODE TIMER SLEEP F SWING AN SPEED Display COOLING FAN HEAT HOURS MINUTES TEMPERATURE ...

Страница 6: ... Assemble the hot air hose on the unit Clip on the water atom izer at the end of the spiral pipe to the holder Unfold flexible hose with attached hose adapter connector and snap into Window Slide Bar AutoDrain NanoMist Technology Assembly 2 3 6 8 4 5 7 1 Attach Window Slide Bar Connector to Exhaust Hose by twisting as shown Only Required For Disassembly In order to unlock the quick connector push ...

Страница 7: ... hose to the unit by turning it clockwise at least 5 turns Similarly connect the hose to the slide bar connector as far as possible Place the telescopic slide bar in the open window or door and adjust the length to fill as much open space as possible Put the slide bar connector in the opening in the telescopic slide bar Close the window or door as much as possible to prevent outside air entering t...

Страница 8: ...sired mode is appearing Cool Fan Heat etc On the LCD display you will see Cooling Fan only Heat Each time the unit starts it starts operating in cool mode with a set temperature of 22 C The fan speed will be selected automatically Fan speed If you prefer a constant fan speed instead of the auto fan speed press the button successively the fan speed icon on the LCD display will rotate accordingly Fa...

Страница 9: ...d ON when the unit is RUNNING Perform the standard steps as described above Repeat the above procedure while the digits are still flashing for setting the ON The linear time scale will be ON between 00 00 to the time set with the timer to OFF and from the ON time until 24 00 The flashing bar on the time scale indicates the real time and moves a segment ahead every 30 minutes The unit will operate ...

Страница 10: ... stop and the louvres remain in that position The direction of the air flow is then constant When the OFF button is pressed the louvres close This way of directing the air flow is particularly convenient when using the remote control a user friendly approach to your comfort In order to direct the air flow to a lower angle raise the louvres housing by pulling it up only by the centre of its back ri...

Страница 11: ...is almost identical to the operation by the control panel The only exception is the clock function Instead of the button for setting the actual time and for programming the timer there are 3 push buttons on the remote control as follows for setting the actual time TIMER ON for programming the time when the unit is ON TIMER OFF for programming the time when the unit is OFF Remote control ...

Страница 12: ...rs in the upper and lower air inlet should be cleaned regularly by rinsing them under running water b The positive negative electrostatically charged 3M High Air Flow filter is recommended to be changed every 3 months Unusual dirt construction work pets the presence of smoke and running the air conditioning unit continuously can shorten the life time of the 3M High Air Flow filter c The active car...

Страница 13: ...e water container on the floor underneath the permanent drainage point Remove the water stopper and rubber plug from the drain and let the water run out The water container has to be emptied several times before all water will be drained ca 1 5 litres Replace the rubber plug and water stopper put the plug into the wall socket and switch the unit on The warning signal should be off NOTE Remove the ...

Страница 14: ...m to perform In direct sunlight Close curtains Windows or doors open many people or a heat source in the room Close doors and windows place an extra air conditioner Dirty filter Clean or replace the filter s Air inlet or air outlet blocked Remove the blockage Room temperature lower than the selected value Change temperature selection The unit is noisy Unit stands uneven Place on an even solid surf...

Страница 15: ... Current Cooling A 3 7 4 8 6 5 Current Heating A 3 9 5 2 6 0 Mains V Hz PH 220 240 V 50 1 Compressor model Rotary Fan speeds 3 2 1 turbo Thermostat range ºC 18 32 Operating temperature range ºC 5 35 Refrigerant R410A g 340 560 660 Dimensiones w x h x d mm 500 x 815 x 415 Net weight kg 31 2 35 35 8 PLMB 9KEHPW 410 series can be connected only to a supply with system impedance no more than 0 210 Ohm...

Страница 16: ...an unauthorised person The guarantee does not cover accidental damage misuse or consumable items such as filters The guarantee after repair or replacement will not be extended beyond the original two year period All replacement parts or units will be new or reconditioned Parts or units which are replaced become the property of Atlantic Australasia Atlantic Australasia disclaims any liability for i...

Отзывы: