The Generic option is an unsupported choice. It is provided to allow
users the option of attaching a printer of their own choice. 

Printer Speed (H)

Shows the speed of the printer interface.

Printer Data Bits (I)

Shows the number of bits in a byte over the printer interface.

Printer Stop Bits (J)

Shows the number of stop bits in a byte over the printer interface.

Printer Parity (K)

Shows the parity of each data byte over the printer interface.

Printer Flow Control (L)

Shows the flow control being used by the printer.

Go ahead on Buffer Empty (M)

Computers that send data in blocks use this option. After a Block has
been used up (i.e. the buffer is empty) the Telex Unit sends a Go Ahead
(SO) to the Host.

Printer Compulsory (R)

This  option  indicates  whether  the  presence  of  the  printer  overrides
Host  security  such  that  continued  acceptance  of  incoming  calls  is
permitted when the host computer is in fault condition.

Drop Carrier on Line Closed (S)

This option controls the state of the carrier presented to the telex line
under  a  Closed  Line  condition.  The  default  value  leaves  the  carrier
enabled in a Closed Line condition.

Automatic Reset (T)

The  default  value  for  this  option  means  that  a  soft  reset  command,
(ESC)  A,  is  required  to  put  the  unit  into  idle  state  from  a  power  up
state.  This is the normal operation of the telex unit when driven by
most applications. By enabling this option, the telex unit goes directly
on line without requiring a reset command.

Previous Line (X)

Used  when  in  prompted  mode  for  displaying  the  previous
configuration parameter.

13

Содержание ATU Telex Unit

Страница 1: ...1 Telex Unit ATU ...

Страница 2: ...not represent a commitment on the part of ATL Telecom Ltd No liability is accepted for any consequential losses resulting from errors or omissions from this document Head Office Sales Support Office ATL Telecom Limited Cypress Drive St Mellons Cardiff CF3 0EG UK Tel 44 0 29 20500700 Fax 44 0 29 20500701 2 ...

Страница 3: ...ION MANUAL CONTENTS CE COMPLIANCE STATEMENTS SAFETY INSTRUCTIONS EMC WARNING STATEMENTS 1 INTRODUCTION 2 INSTALLATION STEPS 3 HOST SIDE CONNECTION DETAILS 4 CONFIGURATION 5 LED DISPLAY 6 USER RESPONSIBILITIES ATL Part No 1 267 000 610 ISSUE 4 March 2003 ...

Страница 4: ...asily accessible 3 For continued protection against risk of fire replace with same type and rating fuse 4 The TELEX LINE connection has a safety status of TNV3 the Host and Printer AUX Interface port D Type connections have a safety status of EARTHED SELV and the mains connection has an EARTHED HAZARDOUS VOLTAGE STATUS SYSTEM SPECIFICATION The ATU is defined as a Front End Telex Terminal Apparatus...

Страница 5: ...e lithium battery incorporated inside the ATU unit will react violently with water and most gases It is also important that batteries are not crushed incinerated or disposed of with normal waste Therefore the battery is classed as being NOT USER REPLACEABLE and the equipment should be returned to the manufacturer or agent if battery replacement is required 5 MANUFACTURERS DECLARATION ATL Telecom L...

Страница 6: ... with any installation instructions issued by the Host equipment manufacturer There is only one control on the Telex Unit the RESET button that allows the user to execute a hardware reset of the Telex Unit Commands from the Host carry out any other necessary changes in its operating mode These include a reset command which must be entered each time the Telex Unit is powered up or the RESET button ...

Страница 7: ...within cable reach of the mains supply host equipment telex line termination and standby teleprinter if installed The mains lead and telex connections provided with the Telex Unit are approximately 2 meters long The chosen site should be secure dry and avoid exposure to excessive heat from equipment room heating devices or direct sunlight The front panel should be visible so that the LED displays ...

Страница 8: ...e Telex Unit and the method of security checking and flow control is correct mode of operation See section 3 for details vi Check Message After the HOST LED s have been extinguished the Telex Unit is ready for use in accordance with the Telex operating instructions for the host equipment If possible a test telex should be sent to another known location as a check that the system is operating corre...

Страница 9: ...s for XON XOFF Security Checking by use of ENQ ACK This method of security checking involves the regular exchange of control characters between the Telex Unit and the Host The Telex Unit sends a Confidence Check enquiry character ENQ to the Host and expects to receive an OK character ACK in response After sending an ENQ the Telex Unit checks to see if an ACK has been received The Host must reply w...

Страница 10: ...a 9 pin Female D type connector Pin AUX 1 Earth 2 Rx from unit to printer 3 TX not used in printer mode 4 DTR to the unit 5 0V common 6 DSR from the unit 7 RTS to the unit 4 CONFIGURATION Configuring the ATL Telex Unit The ATL Telex Unit is configured by changing the various options in the unit s software configuration menu accessed from a terminal session through the Host port This section contai...

Страница 11: ...ticular installation Once configured the parameters will remain stored in non volatile memory for immediate use after power on The menu may be accessed from a dumb terminal connected to the Host port or direct from the Host system if this option is possible After sending ESC Z the Host must send either 0 which means no prompts or 1 which means prompts The following power up software reset defaults...

Страница 12: ...ach byte Host Parity D Shows the Parity of each data byte Host Security E Shows the security being used by Host computer See section 3 for more information Host Flow Control Security F Shows the flow control being used by Host computer See section 3 for more information Printer Selected G Shows which printer has been selected for connection on the Auxiliary Port Note ATL will only provide support ...

Страница 13: ...Ahead SO to the Host Printer Compulsory R This option indicates whether the presence of the printer overrides Host security such that continued acceptance of incoming calls is permitted when the host computer is in fault condition Drop Carrier on Line Closed S This option controls the state of the carrier presented to the telex line under a Closed Line condition The default value leaves the carrie...

Страница 14: ...e unit In all cases except if Automatic Reset option is enabled the unit will initialise and send the R ENTER RESET message to the Host The unit is then brought back on line by sending ESC A If speed changes are made these are functional from the start of the output of the R ENTER RESET message 5 LED DISPLAY The 5 LED s on the Telex Unit front panel provide a visual indication of the operational s...

Страница 15: ...ion LINE NUMBER AND ANSWERBACK 1 The user is responsible for ensuring that the ATU is equipped with the line number and answerback agreed with the PTO for the circuit to which it is connected 2 The user shall not insert or change the line number and answerback but shall approach the supplier for this work to be undertaken 3 The user is responsible for ensuring that on any one line only the line nu...

Страница 16: ...16 THE INFORMATION CONTAINED IN THIS DOCUMENT IS CONFIDENTIAL TO ATL TELECOM LTD AND MAY NOT BE DISCLOSED OR REPRODUCED IN WHOLE OR IN PART WITHOUT THEIR WRITTEN CONSENT ATL TELECOM LTD 2003 ...

Отзывы: