Agency Listings
AD‑28X‑MV
UL (UJPX), (UJPX7), (UXPL, Marine) ‑
For indoor or outdoor use in Class I, Groups
A, B, C and D, Division 2; Class II, Groups
F and G, Division 2; Class III hazardous
locations; Type 4X enclosure.
T-Code at Maximum Ambient Temperature, °C
Hazardous Location
40° C
65° C
Class I, Division 2, Groups A, B, C, D
T6
T5
Class II, Division 2, Groups F, G
T6
T5
Class III
T6
T5
EXPLOSION HAZARD – SUBSTITUTION OF COMPONENTS MAY IMPAIR
SUITABILITY FOR CLASS I, DIVISION 2.
B. Unpacking.
After unpacking the Model AD‑28X‑MV, examine it for damage that may have occurred in
transit. If the equipment has been damaged, do not attempt to install or operate it, file a claim
immediately with the carrier stating the extent of the damage. Carefully check all envelopes,
shipping labels and tags before removing or destroying them.
Before attempting to install the intercom, be sure that all parts listed in the KIT CONTENTS
LIST have been supplied.
C. Kit Contents List.
Qty.
Description
Part Number
1
Wiring block
140A326‑01
4
Screws, Phillips head
7000478‑10
4
Lockwashers
7074A010
1
Resistor, 1K, 1W
101216
D. Mounting.
The selection of the mounting location for the device, its controls and the rout‑
ing of the wiring is to be accomplished under the direction of the facilities and
the safety engineer.
The intercom is intended to be mounted on any relatively flat and rigid surface by the two
mounting ears on the exterior of the housing. Figure 5 is a dimensional outline drawing show‑
ing the proper mounting configuration. The two mounting ears have slots for 3/8
"
(M10) bolts
spaced 5‑5/8
"
to 5‑7/8
"
(14.3 cm to 14.9 cm) apart. Hardware for mounting the intercom to the
surface is left up to the installer.
This unit is heavy and should be mounted on a rigid surface capable of sup‑
porting the weight of the intercom.