background image

 

 

 

 

 
 

 
 

 

 

ATIM Cloud Wireless

®

 

Infrared Presence - PIR          

User Guide 

 

Concerned models:  

ACW-PIR360-I 

ACW-PIR90-I 

ACW-PIR180-O 

ACW-PIR90-O 

ACW-ILB30 

ACW-ILB100 

Содержание ACW-ILB100

Страница 1: ...ATIM Cloud Wireless Infrared Presence PIR User Guide Concerned models ACW PIR360 I ACW PIR90 I ACW PIR180 O ACW PIR90 O ACW ILB30 ACW ILB100...

Страница 2: ...6 a Consumption 6 b Power Supply 6 Operating modes of the PIR 7 a Counting mode 7 b Alarm mode 8 First startup 9 a Power up 9 b Test frame emission 9 Frame fromat 10 a Lists of the frames 10 b Standa...

Страница 3: ...nt on the part of ATIM radiocommunications ATIM radiocommunications provides this document as is with no warranty of any kind express or implied including but not limited to implied warranties of merc...

Страница 4: ...EN300 220 1 v2 4 1 Environmental recommendations a Explosive atmosphere Except for the ACW ATEX line specifically intended for this purpose do not use ACW radio modems in the presence of flammable gas...

Страница 5: ...Union This symbol appears on a product or its packaging to indicate that the product may not be discarded with another household waste Rather it is your responsibility to dispose of this product by b...

Страница 6: ...er to the Optex documentation below CAUTION On some products it is possible via switches to configure the default states of the dry contacts NO NC COM To guarantee the correct functioning of the radio...

Страница 7: ...0 LoRa 400 A 30mA 60mA Sigfox 400 A 17mA 21mA b Power Supply The indoor I and outdoor O PIR ranges all use the same lithium battery model 3v6 format 2 3AA CAUTION Do not use other models otherwise the...

Страница 8: ...rn more about the detection method Product Minimum time between 2 detections ACW PIR360 I 2 minutes ACW PIR90 I 2 minutes ACW PIR180 O 5s minimum 120s recommended ACW PIR90 O 5s minimum 120s recommend...

Страница 9: ...nutes ACW PIR180 O 5s minimum 120s recommanded ACW PIR90 O 5s minimum 120s recommanded ACW ILB30 5s minimum 120s recommanded ACW ILB100 5s minimum 120s recommanded NOTE ISM band regulations impose a l...

Страница 10: ...to the Optex manual of the product concerned for more details and close the product b Test frame emission When powered on for the first time the product tries to connect to the network Once it is conn...

Страница 11: ...Description 0 0x32 Header 1 0x01 Casing opening frame 0x08 Alarm frame 0x10 Counting frame 2 0x00 Casing opening sensor low state 4 0x01 Casing opening sensor high state 4 3 0xFF Unused 4 0x00 DQ sens...

Страница 12: ...deals with carriage return enter key it is represented by the hexadecimal code 0x0a0d Example We want to send ATO120 3C ATOS ATR Then the following code should be sent 41544f3132303d33430a0d41544f530...

Страница 13: ...es long and are structured the same way 3 pairs address value allowing to modify up to 3 ATO registers As the Downlinks are necessarily 8 bytes to record less than 3 registers you must indicate the sa...

Страница 14: ...19 ATO120 XX ACW ILB100 Counting ATO101 11 ATO120 XX Alarm ATO101 1D ATO120 XX ATO120 XX with XX the transmission period in minutes in hexadecimal Example for a period of 10 minutes ATO120 0A In alarm...

Страница 15: ...erature if a T C sensor is integrated into the product and to obtain Downlink windows ATO16 0A is recommended for counting mode one frame every 10 minutes ATO16 3C is recommended in alarm mode to have...

Страница 16: ...to your subscription with Sigfox you will have to register your device yourself on the Sigfox online portal Here is a quick procedure allowing you to register your product on the Sigfox network For mo...

Страница 17: ...nt to register on your Sigfox account Your product is now being imported into your SIGFOX account The import can take several hours Identifiant Sigfox Code PAC Sigfox Num ro de certificat Sigfox de vo...

Страница 18: ...ver the air activation when the product is powered on a joining request to a LoRa network is sent The device must first be provisioned on the required network at one of the operators Orange or Objenio...

Страница 19: ...f the device has been commissioned on the network Check if the network coverage is good enough for the device to transmit Check is the green LED blinks when emissions LoRa version Technical support Fo...

Отзывы: